Installer Setting-Group Setting

It is a function for settings in group control, or 2-remote controller control.
Please donʼt set this function in case of non-group control.
Remote controller
Master
Slave
When controlling in groups, basic operation settings, airflow strength weak/medium/strong,
lock setting of the remote controller, time settings, and other functions may be restricted.
If pressing
1
seconds, it enters into remote
controller setter setup mode.
- If pressing once shortly, it enters
into user setup mode. Please press
more than 3 seconds for sure.
If pressing
2
master/slave selection menu as picture
below.
Select Master/ Slave by pressing
3
button.
(00: Slave, 01: Master)
Function Code
Press
4
5
Pressing
❈ After setup, it automatically gets out of
setup mode if there is no button input for
25 seconds.
❈ When exiting without pressing set button,
the manipulated value is not reflected.
Indoor unit operates based on master remote controller at group control.
(Master is set when delivering from the warehouse.)
Setup all remote controllers except one master remote controller to slave at
group control
Optional Operation
button long for 3
button repeatedly, it moves to
Master/Slave value
button to save.
button will exit settings mode.