Greenlee 5778 Operation, Service And Parts Instruction Manual page 6

Megohmmeter
Table of Contents

Advertisement

Available languages

Available languages

Megohmmeter Test
1. Visually inspect the tester, test leads,
and alligator clips.
2. Plug the red test lead into the positive
jack, and plug the black test lead into
the negative jack.
Note: Be sure that the clips do not
3. Press the 1000 volt selector switch.
4. Turn the crank clockwise approximately
2-1/2 to 3 turns per second. The
pointer should move to the right-hand
side of the scale (toward the infinity
mark). Any other reading indicates that
the test leads are damaged or the
megohmmeter needs repair.
5. Connect the alligator clips together.
Turn the crank clockwise approxi-
mately 2-1/2 to 3 turns per second.
The pointer should move to the left-
hand side of the scale (toward zero).
Any other reading indicates that the
test leads are damaged.
Setup
Note: Refer the manufacturer's
1. Shut off and disconnect power. Make
sure all capacitors are fully discharged.
Voltage must not be present.
2. Select the test range on the
megohmmeter to twice the operating
voltage for the device under test.
6
Greenlee Textron / Subsidiary of Textron Inc.
contact anything.
specifications to find the
operating voltage of the device
under test.
5778 Megohmmeter

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents