Start-Up And Adjustment; Preliminary Inspections; Lighting Instructions - American Standard UHMB080ACV3VB Series Installer's Manual

Upflow/ horizontal and downflow/ horizontal, gas-fired, direct vent, variable speed inducer, modulating condensing communicating furnaces
Hide thumbs Also See for UHMB080ACV3VB Series:
Table of Contents

Advertisement

REINSTALLATION OF THE BURNER BOX COVER
Figure 55 shows the correct way to reinstall the Burner
Box cover if adjustment or replacement of the Flame
Sensor, Hot Surface Igniter, or Main Burner orifices have
required removal of the cover.
START-UP AND ADJUSTMENT
PRELIMINARY INSPECTIONS
WARNING
s
s
!
ELECTRICAL SHOCK HAZARD
Disconnect  power  to  the  unit  before  removing  the  blower 
door. Allow  a  minimum  of  10  seconds  for  IFC  power  supply  to 
discharge to 0 volts.
Failure  to  follow  this  warning  could  result  in  property  damage, 
personal injury or death.
NOTE: The condensate trap must be primed before
operation.
With gas and electrical power "OFF"
1. Duct connections are properly sealed.
2. Filters are in place.
3. Venting is properly assembled.
4. Blower door is in place.
Turn the main Gas Valve toggle switch (See Figure 59)
within the unit to the "OFF" position. Turn the external
shutoff valve to the "OPEN" position (See Figures 50 and
52). Purge the air from the gas lines. After purging, check
all gas connections for leaks with a soapy solution — DO 
NOT CHECK WITH AN OPEN FLAME. Allow 5 minutes for any
T
ROTATE THE FRONT 
COVER AS SHOWN
INSERT THE TOP FLANGE OF 
THE FRONT COVER UNDER 
THE LIP INSIDE THE BOX
ALL SIDE FLANGES MUST BE 
OUTSIDE OF THE BOX
ROTATE THE FRONT COVER IN-
WARD MAKING SURE THAT ALL 
SIDE FLANGES ARE OUTSIDE 
OF THE BOX.
18-CD30D1-20-EN
Installer's Guide
gas that might have escaped to dissipate. LP Gas being
heavier than air may require forced ventilation. Turn the
toggle switch on the Gas Valve in the unit to the "ON"
position.
All soap solution should be cleaned off gas piping after
gas leak testing is complete.
LIGHTING INSTRUCTIONS
WARNING
s
s
!
FIRE OR EXPLOSION HAZARD
Do NOT attempt to manually light the burner.
Failure to follow this warning could result in property damage, 
personal injury or death.
!
CAUTION
s
s
Whenever your house is to be vacant, arrange to have someone 
inspect your house for proper temperature. This is very 
important during freezing weather. If for any reason your furnace 
should fail to operate damage could result, such as frozen water 
pipes.
Lighting
instructions
appear
installation must be checked out at the time of initial start
up to insure proper operation of all components. Check
out should include putting the unit through one complete
cycle as outlined below.
Turn on the main electrical supply and set the Comfort
Control above the indicated temperature. The Ignitor will
automatically heat, then the Gas Valve is energized to
permit the flow of gas to the burners. After ignition and
flame is established, the Flame Control Module monitors
the flame and supplies power to the Gas Valve until the
Comfort Control is satisfied.
TO SHUT OFF
For complete shutdown: Turn the Gas Valve toggle switch
on the main Gas Valve to the "OFF" position (See Figures
59). Disconnect the electrical supply to the unit.
s
s
!
CAUTION
If complete shutdown is done during the cold weather months, 
provisions must be taken to prevent freeze-up of all water pipes 
and water receptacles.
NOTE:
Natural gas units should not have any yellow tipped
flames. This condition indicates that a service call is
required. For best operation, burners must be cleaned
annually using brushes and vacuum cleaner.
on
each
unit.
Each
39