Service Facts
Gas Furnace – Var. Speed Blower –
Var. Speed Inducer – Two Stage Heat –

Direct Vent

Models:
* - First letter may be "A" or "T"
*UY060R9V3W
*DY060R9V3W
*UY080R9V3W
*DY080R9V3W
*UY100R9V4W
*DY100R9V4W
*UY120R9V5W
*DY120R9V5W
IMPORTANT — This document contains a wiring diagram and service information. This is customer property and is to
remain with this unit. Please return to service information pack upon completion of work.
WARNING
MODEL
TYPE
RATINGS 2
1st Stage Input BTUH
1st Stage Capacity BTUH (ICS) 3
2nd Stage Input BTUH
2nd Stage Capacity BTUH (ICS) 3
Temp. rise (Min.-Max.) °F.
BLOWER DRIVE
Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R. P .M.
Volts / Ph / Hz
COMBUSTION FAN - Type
Drive - No. Speeds
Motor HP - RPM
Volts / Ph / Hz
FLA
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
VENT — Size (in.)
HEAT EXCHANGER
Type -Fired
-Unfired
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V / Ph / Hz 4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs)
1 Central Furnace heating designs are certified by AGA and CSA.
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.
For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3 Based on U.S. government standard tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
NOTICE: Since the manufacturer has a policy of continuous product and product data improvement,
it reserves the right to change design and specifications without notice.
© 2005 American Standard Inc. All Rights Reserved
DISCONNECT POWER BEFORE SERVICING
*UY060R9V3W
Upflow / Horizontal
Upflow / Horizontal
39,000
37,000
60,000
56,000
35 - 65
DIRECT
10 x 8
1
Variable
See Fan Performance Table
See Fan Performance Table
1/2
Variable
115/1/60
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
33 - 110/3/60 - 180
1.0
Yes
High Velocity
1 - 17x25 - 1 in.
2 Round
Aluminized Steel - Type I
Aluminized Steel - Type I
20
3 — 45
3 — 56
Redundant - Two Stage
Redundant - Two Stage
Hot Surface Igniter
Multiport Inshot
3
115/1/60
11.1
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
41-3/4 x 19-1/2 x 30-1/2
158 / 146
1
*UY080R9V3W
*UY100R9V4W
Upflow / Horizontal
52,000
48,000
80,000
73,000
35 - 65
DIRECT
10 x 8
1
Variable
See Fan Performance Table
1/2
Variable
115/1/60
Centrifugal
Centrifugal
Direct - Variable
Direct - Variable
1/50 - 5000
1/50 - 5000
33 - 110/3/60 - 180
1.0
Yes
High Velocity
High Velocity
1 - 17x25 - 1 in.
1 - 20x25 - 1 in.
2 Round
Aluminized Steel - Type I
20
4 — 45
4 — 56
Redundant - Two Stage
Hot Surface Igniter
Hot Surface Igniter
Multiport Inshot
Multiport Inshot
4
115/1/60
11.1
15
1/2
H x W x D
H x W x D
41-3/4 x 23 x 30-1/2
168 / 156
X3 4 1 1 1 9 P1 2
*UY120R9V5W
Upflow / Horizontal
65,000
78,000
60,000
72,000
100,000
120,000
93,000
112,000
35 - 65
40 - 70
DIRECT
DIRECT
10 x 10
10 x 10
1
1
Variable
Variable
See Fan Performance Table
1
1
Variable
Variable
115/1/60
115/1/60
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
1.0
Yes
Yes
High Velocity
1 - 24x25 - 1 in.
3 Round
3 Round
Aluminized Steel - Type I
20
20
5 — 45
6 — 45
5 — 56
6 — 56
Redundant - Two Stage
Hot Surface Igniter
Multiport Inshot
5
6
115/1/60
115/1/60
13.5
15.2
20
20
1/2
1/2
H x W x D
41-3/4 x 26-1/2 x 30-1/2
197 / 185
206 / 193
Page B-651-438
W.M. 1/05R

Advertisement

Table of Contents
loading

Summary of Contents for American Standard AUY060R9V3W

  • Page 1: Direct Vent

    4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. NOTICE: Since the manufacturer has a policy of continuous product and product data improvement, it reserves the right to change design and specifications without notice. Page B-651-438 W.M. 1/05R © 2005 American Standard Inc. All Rights Reserved...
  • Page 2 Service Facts PRODUCT SPECIFICATIONS MODEL *DY060R9V3W *DY080R9V3W *DY100R9V4W *DY120R9V5W TYPE Downflow / Horizontal Downflow / Horizontal Downflow / Horizontal Downflow / Horizontal RATINGS 2 1st Stage Input BTUH 39,000 52,000 65,000 78,000 1st Stage Capacity BTUH (ICS) 3 36,000 48,000 60,000 72,000 2nd Stage Input BTUH...
  • Page 3: Safety Section

    Service Facts SAFETY SECTION WARNING WARNING CARBON MONOXIDE POISONING HAZARD CARBON MONOXIDE POISONING HAZARD Failure to follow the steps outlined below for each Failure to follow the installation instructions for the venting appliance connected to the venting system being system being placed into operation could result in carbon placed into operation could result in carbon monoxide monoxide poisoning or death.
  • Page 4 Service Facts SEQUENCE OF OPERATION INDOOR BLOWER TIMING Heating: The integrated furnace control module controls Thermostat call for heat (2-stage thermostat) the indoor blower. The blower start is fixed at 45 seconds Call for 1st stage only: after ignition. The FAN-OFF period is field selectable by W1 thermostat contacts close signaling the control module to dip switches SW-2, #1 and #2 at 60, 100, 140, or 180 run its self-check routine.
  • Page 5 Service Facts PERIODIC SERVICING REQUIREMENTS NOTE: WARNING On LP (propane) units, some light yellow tipping of the Disconnect power to the unit before removing the blower outer mantle is normal. Inner mantle should be bright blue. door. Allow a minimum of 10 seconds for IFC power supply Natural gas units should not have any yellow tipped flames.
  • Page 6 Service Facts *UY WIRING DIAGRAM Page B-651-438...
  • Page 7 Service Facts *UY SCHEMATIC DIAGRAM Page B-651-438...
  • Page 8 Service Facts *DY WIRING DIAGRAM Page B-651-438...
  • Page 9 Service Facts *DY SCHEMATIC DIAGRAM Page B-651-438...
  • Page 10 Service Facts *UY060R9V3W FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st Stage Capacity = 37,000 2nd Stage Capacity = 56,000 DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW SETTING SW 7 SW 8 TEMP. RISE WATTS MEDIUM LOW TEMP.
  • Page 11 Service Facts *UY080R9V3W FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st Stage Capacity = 49,000 2nd Stage Capacity = 73,000 DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW SETTING SW 7 SW 8 TEMP. RISE WATTS MEDIUM LOW TEMP.
  • Page 12 Service Facts *UY100R9V4W FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st Stage Capacity = 62,000 2nd Stage Capacity = 93,000 DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW SETTING SW 7 SW 8 TEMP. RISE WATTS 1006 1022...
  • Page 13 Service Facts *UY120R9V5W FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st Stage Capacity = 74,000 2nd Stage Capacity = 112,000 DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW SETTING SW 7 SW 8 1090 1120 1080 1070 1010...
  • Page 14 Service Facts *DY060R9V3W FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st STAGE CAPACITY = 37,000 2nd STAGE CAPACITY = 56,000 DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW SETTING SW 7 SW 8 TEMP. RISE WATTS MEDIUM LOW TEMP.
  • Page 15 Service Facts *DY080R9V3W FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st STAGE CAPACITY = 49,000 2nd STAGE CAPACITY = 73,000 DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW SETTING SW 7 SW 8 TEMP. RISE WATTS MEDIUM LOW TEMP.
  • Page 16 Service Facts *DY100R9V4W - FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st STAGE CAPACITY = 62,000 2nd STAGE CAPACITY = 93,000 DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW SETTING SW 7 SW 8 TEMP. RISE WATTS 1020 1047...
  • Page 17 Service Facts *DY120R9V5W - FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st STAGE CAPACITY = 74,000 2nd STAGE CAPACITY = 112,000 DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW SETTING SW 8 SW 7 1025 1025 1000 1000...
  • Page 18 IFC Error Flash Codes Service Facts INTEGRATED FURNACE CONTROL RED LED "ERROR" FLASH CODES 2 Flashes --- System Lockout (Retries or Recycles exceeded) Draft Pressure Error - Possible problems: a) Venting problem 3 Flashes --- b) Pressure switch problem c) Inducer problem 4 Flashes --- Open Temperature Limit Switch 5 Flashes ---...
  • Page 19 Service Facts NOTES Page B-651-438...
  • Page 20 American Standard Inc. P.I. 6200 Troup Highway Tyler, TX 75707 Since the manufacturer has a policy of continuous product and product data improvement, it reserves the right to For more information contact your local dealer (distributor) change design and specifications without notice.