American Standard TUE040A924L Service Manual

Upflow & downflow – induced draft 1 stage heat

Advertisement

Service Facts
Gas Furnaces
Upflow & Downflow – Induced Draft
1 Stage Heat
Models:
TUE040A924L
TUE100A948L
TUE060A936L
TUE100A960L
TUE080A936L
TUE120A960L
TUE080A948L
TUE140A960L
TUE100A936L
IMPORTANT — This document contains a wiring diagram and service information. This is customer property and is to
remain with this unit. Please return to service information pack upon completion of work.
WARNING
MODEL
TYPE
RATINGS 2
Input BTUH 3
Capacity BTUH (ICS) 3
Temp. rise (Min.-Max.) °F.
BLOWER DRIVE
Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts / Ph / Hz
COMBUSTION FAN - Type
Drive - No. Speeds
Motor HP - RPM
Volts / Ph / Hz
FLA
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
VENT — Size (in.)
HEAT EXCHANGER
Type - Fired
- Unfired
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V / Ph / Hz 4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs.)
**TUE060A936L0 was built with a 10 X 7 blower housing, however the 10 X 7 and 10 X 6 have identical airflow in this model.
1 Central Furnace heating designs are certified by AGA and CSA.
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications,
above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3 Based on U.S. government standard tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
NOTICE: Since the manufacturer has a policy of continuous product and product data improvement,
it reserves the right to change design and specifications without notice.
© 2003 American Standard Inc. All Rights Reserved
TDE060A936M
TDE080A945M
TDE100A945M
TDE100A960M
TDE120A960M
DISCONNECT POWER BEFORE SERVICING
PRODUCT SPECIFICATIONS
TUE040A924L
Upflow / Horizontal
40,000
31,000
30 - 60
Direct
10 x 6
1
4
See Fan Performance Table
1/5
1080
115/1/60
Centrifugal
Direct - 1
1/50 - 3180
115/1/60
1.09
No
High Velocity
1 - 16x25 - 1 in.
4 Round
Alum. Steel
-
20
2 — 45
2 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
2
115/1/60
5.4
15
1/2
H x W x D
41-3/4 x 16-1/2 x 30-1/2
119 / 110
1
TUE060A936L
Upflow / Horizontal
60,000
47,000
30 - 60
Direct
10 x 6**
1
4
See Fan Performance Table
1/3
1075
115/1/60
Centrifugal
Direct - 1
1/50 - 3180
115/1/60
1.09
No
High Velocity
1 - 16x25 - 1 in.
4 Round
Alum. Steel
20
3 — 45
3 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
3
115/1/60
9.0
15
1/2
H x W x D
41-3/4 x 16-1/2 x 30-1/2
127 / 118
X341001P09
TUE080A936L
Upflow / Horizontal
80,000
63,000
30 - 60
Direct
10 x 7
1
4
See Fan Performance Table
1/3
1075
115/1/60
Centrifugal
Direct - 1
1/50 - 3180
115/1/60
1.09
No
High Velocity
1 - 17x25 - 1 in.
4 Round
Alum. Steel
20
4 — 45
4 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
4
115/1/60
9.0
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
142 / 132
Page B-635-422
P.I. 9/03

Advertisement

Table of Contents
loading

Summary of Contents for American Standard TUE040A924L

  • Page 1 4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. NOTICE: Since the manufacturer has a policy of continuous product and product data improvement, it reserves the right to change design and specifications without notice. Page B-635-422 P.I. 9/03 © 2003 American Standard Inc. All Rights Reserved...
  • Page 2 Service Facts PRODUCT SPECIFICATIONS MODEL TUE080A948L TUE100A936L TUE100A948L TYPE Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal RATINGS 2 Input BTUH 3 80,000 100,000 100,000 Capacity BTUH (ICS) 3 64,000 79,000 79,000 Temp. rise (Min.-Max.) °F. 30 - 60 40 - 70 35 - 65 BLOWER DRIVE...
  • Page 3: Product Specifications

    Service Facts PRODUCT SPECIFICATIONS MODEL TDE060A936M TDE080A945M TDE100A945M TYPE Downflow / Horizontal Downflow / Horizontal Downflow / Horizontal RATINGS 2 Input BTUH 3 60,000 80,000 100,000 Capacity BTUH (ICS) 3 48,000 64,000 80,000 Temp. rise (Min.-Max.) °F. 30 - 60 35 - 65 35 - 65 BLOWER DRIVE...
  • Page 4: Safety Section

    Service Facts SAFETY SECTION ▲ ▲ WARNING WARNING CARBON MONOXIDE POISONING HAZARD The cabinet must have an uninterrupted or unbroken ground according to National Electrical Code, ANSI/NFPA 70 - Failure to follow the steps outlined below for each “latest edition” and Canadian Electrical Code, CSA C22.1 or appliance connected to the venting system being local codes to minimize personal injury if an electrical fault placed into operation could result in carbon monoxide...
  • Page 5: Periodic Servicing Requirements

    Service Facts PERIODIC SERVICING REQUIREMENTS 1. GENERAL INSPECTION — Examine the furnace NOTE: installation annually for the following items: On LP (propane) units, due to variations in BTU content and altitude, servicing may be required at shorter intervals. a. All flue product carrying areas external to the furnace (i.e.
  • Page 6: Wiring Diagram

    Service Facts WIRING DIAGRAM From Dwg. D341828 Rev. 1 (continued on next page) Page B-635-422...
  • Page 7: Schematic Diagram

    Service Facts SCHEMATIC DIAGRAM From Dwg. D341828 Rev. 1 Page B-635-422...
  • Page 8 Service Facts WIRING DIAGRAM From Dwg. D341830 Rev. 1 (continued on next page) Page B-635-422...
  • Page 9 Service Facts SCHEMATIC DIAGRAM From Dwg. D341830 Rev. 1 Page B-635-422...
  • Page 10: Furnace Airflow (Cfm) Vs. External Static Pressure (In. W.c.)

    CFM VS. TEMPERATURE RISE CFM (CUBIC FEET PER MINUTE) MODEL 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 TUE040A924L 54 49 42 37 33 TUE060A936L 56 49 TUE080A936L...
  • Page 11: Furnace Airflow (Cfm) Vs. Static Pressure (Ins. W.g.)

    Service Facts FURNACE AIRFLOW (CFM) VS. STATIC PRESSURE (ins. w.g.) MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 HIGH - Black 1480 1429 1376 1318 1282 1188 1112 1029 MED.-HIGH - Blue 1302 1276 1229 1188 1141 1088 1024...
  • Page 12: Abnormal Conditions

    If symptoms persist, seek medical attention. Skin Contact – Wash affected areas gently with soap and warm water after handling. American Standard Inc. P.I. 6200 Troup Highway Tyler, TX 75707 Since the manufacturer has a policy of continuous product and product data improvement, it reserves the right...

Table of Contents