Venting Routed Through A Masonry Chimney - American Standard UHMB080ACV3VB Series Installer's Manual

Upflow/ horizontal and downflow/ horizontal, gas-fired, direct vent, variable speed inducer, modulating condensing communicating furnaces
Hide thumbs Also See for UHMB080ACV3VB Series:
Table of Contents

Advertisement

,
PVC PLASTIC VENTING
.
THROUGH UNUSED CHIMNEY
IMPORTANT –
Refer to Section 12.6.8 of NFPA 54 / ANSI 223.1 2012
when routing vent piping through a chimney.
STAINLESS
STEEL
VENT CAP
(OPTIONAL)
SEE CAUTION
FLUE PIPE
COUPLING TO SUPPORT
PIPE FROM ANGLES
OR OTHER SUITABLE
SUPPORT METHOD
FLUE PIPE
IMPORTANT –
The single wall flue pipe joints must be sealed.
The 90° elbow connection to vertical pipe must be
sealed to prevent condensate leakage to base of
masonry chimney.
6 IN. MIN.
SUPPORT THE SINGLE
WALL FLUE PIPE AND
CENTER IT IN THE
CHIMNEY OPENING WITH
ANGLES AS SHOWN OR
ANOTHER EQUIVALENT
MANNER.
COUPLING
AS REQUIRED
NOTE:
HORIZONTAL VENTING
TO VERTICAL VENTING
VENTING ROUTED THROUGH A MASONRY CHIMNEY
18-CD30D1-20-EN
Installer's Guide
TYPE 29-4C STAINLESS STEEL VENTING
/
THROUGH UNUSED CHIMNEY
IMPORTANT –
Refer to Section 12.6.8 of NFPA 54 / ANSI 223.1 2012
when routing vent piping through a chimney.
STAINLESS
STEEL
VENT CAP
(OPTIONAL)
SEE CAUTION
IMPORTANT –
The single wall flue pipe joints must be sealed.
The 90° elbow connection to vertical pipe must be sealed
to prevent condensate leakage to base of masonry
chimney.
6 IN. MIN.
SUPPORT THE SINGLE WALL
STAINLESS STEEL GAS
VENTING AND CENTER IT IN
THE CHIMNEY OPENING WITH
ANGLES AS SHOWN OR
ANOTHER EQUIVALENT
MANNER.
NOTE:
HORIZONTAL VENTING
TO VERTICAL VENTING
27