This table is created using the maximum capacity.
MODEL : AO G14LALL
COOLING
1
Indoor unit is
higher than
outdoor unit.
Height
difference H
(m)
2
Indoor unit is
lower than
outdoor unit.
HEATING
1
Indoor unit is
higher than
outdoor unit.
Height
difference H
(m)
2
Indoor unit is
lower than
outdoor unit.
Indoor unit
Connection pipe
1 Indoor unit is higher than outdoor unit.
5
15
-
10
-
7.5
-
5
0.992
0
1.000
-5
1.000
-7.5
-
-10
-
-15
-
5
15
-
10
-
7.5
-
5
1.000
0
1.000
-5
0.995
-7.5
-
-10
-
-15
-
Height difference H
H
Outdoor unit
- (02 - 07) -
Pipe length (m)
7.5
10
15
-
-
0.953
-
0.983
0.968
0.988
0.987
0.972
0.992
0.991
0.976
1.000
0.999
0.984
1.000
0.999
0.984
1.000
0.999
0.984
-
0.999
0.984
-
-
0.984
Pipe length (m)
7.5
10
15
-
-
0.918
-
0.981
0.918
1.000
0.981
0.918
1.000
0.981
0.918
1.000
0.981
0.918
0.995
0.976
0.914
0.993
0.974
0.912
-
0.972
0.909
-
-
0.900
Outdoor unit
H
Indoor unit
Connection pipe
2 Indoor unit is lower than outdoor unit.
20
25
0.950
0.947
0.966
0.962
0.970
0.966
0.974
0.970
0.982
0.978
0.982
0.978
0.982
0.978
0.982
0.978
0.982
0.978
20
25
0.891
0.862
0.891
0.862
0.891
0.862
0.891
0.862
0.891
0.862
0.886
0.858
0.884
0.856
0.882
0.854
0.873
0.845