(Signals Off Frequency By Just A Few Khz); R.flt (Roofing Filters) - Yaesu FTdx5000MP Operating Manual

Hf/50 mhz transceiver
Table of Contents

Advertisement

I
Narrow-band Roofing Filters of 15 kHz, 6 kHz, 3 kHz, 600 Hz , and 300 Hz bandwidths are provided in the first IF, right
after the first mixer. These filters provide protection for the 2nd mixer, DSP, and other circuitry that follow. The roofing
filter can dramatically improve reception on a very crowded band (during a contest, etc.). Typically, the AUTO selection
mode is satisfactory for most operating situations, but in an extremely crowded phone or CW band you may wish to select
a narrower filter. For example, the 3 kHz roofing filter for SSB operation, or the 600 Hz filter for CW.
: The 600 Hz roofing filter is only available on VFO-A. The 300Hz filter for VFO-A on the FT
other versions.
VFO-A Roofing Filter Setup
Press the [ A ] button (the button will glow red), to acti-
vate the VFO-A receiver.
Move the [ R.FLT ] knob up and down to set the de-
sired bandwidth of the VFO-A Roofing Filter.
The selected bandwidth of the Roofing Filter will be
indicated in the R.FLT column of the Block Diagram
Display.
Press the [ R.FLT ] knob in briefly, to quickly set the
Roofing Filter to the "AUTO" selection. The "AUTO"
mode selects the optimum Roofing Filter, determined
by a combination of the operating mode and the IF
bandwidth. The indicated bandwidth will blink for three
seconds in the Roofing Filter Display, and thereafter
will appear continuously. Typically, the filter will be
set to "AUTO", but may be easily changed when
needed.
[ R.FLT ] Knob
[ A ] Button
A
:
The Roofing Filter selection will be memorized inde-
pendently on each VFO memory in the VFO stack.
Page 56
R
S
R.FLT R
OOFING
O
F
IGNALS
FF
REQUENCY BY
F
ILTERS
VFO-B Roofing Filter Setup
Press the [ B ] button (the button will glow orange), to
activate the VFO-B receiver.
Move the [ R.FLT ] knob up and down to set the de-
sired bandwidth of the VFO-B Roofing Filter.
The selected bandwidth of the Roofing Filter will be
indicated in the R.FLT column of the Block Diagram
Display.
Press the [ R.FLT ] knob in briefly, to quickly set the
Roofing Filter to the "AUTO" selection. The "AUTO"
mode selects the optimum Roofing Filter, determined
by a combination of the operating mode and the IF
bandwidth. The indicated bandwidth will blink for three
seconds in the Roofing Filter Display, and thereafter
will appear continuously. Typically, the filter will be
set to "AUTO", but may be easily changed when
needed.
[ R.FLT ] Knob
T
:
A "Roofing Filter," as its name implies, places a "Roof"
over the receiver's IF system bandwidth. This "Roof" pro-
tects the circuitry downstream from strong signal over-
load interference, just as a roof on a house protects the
contents from rain and snow.
FT
5000 O
DX
J
F
UST A
EW KHZ
5000, is optional on
DX
[ B ] Button
M
PERATING
ANUAL

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ftdx5000Ftdx5000dFtdx5000 series

Table of Contents