Step 10: Burner Test - Thermador PROFESSIONAL PRO GRAND PRD364WLGU Installation Instructions Manual

Dual fuel ranges
Hide thumbs Also See for PROFESSIONAL PRO GRAND PRD364WLGU:
Table of Contents

Advertisement

Available languages

Available languages

5. Mount the Toe Kick Panel on both sides of the unit into
the extruded dimples using the (4) T-20 Torx drill point
screws provided.
Figure 35: Toe Kick Panel Installation
Data Rating Label
The data rating label shows the model and serial number of
the range. It is located in the gap created by the right side
of the oven cavity and the range side panel (Figure 36).
The electric wiring diagrams and schematics are attached
behind the door trim, and should not be removed except by
a service technician, then replaced after service
(Figure 36).
Installation Instructions
Figure 36: Rating Label Location

STEP 10: Burner Test

Install any loose components, such as burner caps and
grates, that may have been removed earlier. Be certain that
burner caps seat properly into the burner bases. Before
testing operation of the appliance, verify that the unit and
the gas supply have been carefully checked for leaks and
that the unit has been connected to the electrical power
supply. Turn the gas shut-off valve to the open position.
NOTICE: All oven knobs and selectors must be set to OFF
before powering up the range. To prevent unintended
operation at power up, please set all oven knobs to OFF.
To ensure customer safety in the event of power failure, the
unit will display an error message upon reinstatement of
power unless all oven knobs are set to OFF. Set all oven
knobs to OFF and reset the breaker to clear the message.
Test Rangetop Burners
Test Burner Ignition
Select a rangetop burner knob. Push down and turn
counterclockwise to HI. The ignitor/spark module will
produce a clicking sound. Once the air has been purged
from the supply lines, the burner should light within four
seconds.
Test Flame: High Setting
Turn burner on to HI. See Figure 37 for appropriate flame
characteristics.
If any of the rangetop burners continue to burn mostly or
completely yellow, verify that the burner cap is positioned
properly on the burner base, then retest. Use caution when
handling the burner caps as they may be hot. If flame
characteristics do not improve, call THERMADOR.
Test Flame: Simmer Setting
Turn burner on to SIM. Verify that the flame travels
completely around the burner. This is known as "carry
over." There should be a flame at each burner port and
there should be no air gap between the flame and the
burner. If any burners do not "carry over," call
THERMADOR.
Four rangetop burners, (2) on the left side and (2) on the
®
right, feature the XLO
setting that causes the flame to
cycle on and off when the knob is set to the XLO range.
This is normal operation.