[3D SETTINGS] menu

On the menu screen, select [3D SETTINGS] from the main menu, and select the item from the
sub-menu.
Refer to "Navigating through the menu" (x page 44) for the operation of the menu screen.
f After selecting the item, press asqw to set.

[3D MODE]

Select a control method of the 3D eyewear for the 3D system in use.
1)
Press as to select [3D MODE].
2)
Press qw to switch [3D MODE].
f The items will switch each time you press the button.
[DLP Link]
[3D SYNC]
[DLP Link + 3D SYNC]
[OFF]
Note
f When viewing 3D images, be sure to select the control method suitable for 3D eyewear in use.
f When viewing 3D images using VESA standard 3D eyewear, connect a compatible IR transmitter correctly.
f When selecting [DLP Link + 3D SYNC] in [3D MODE] and viewing images using VESA standard 3D eyewear, the entire screen may look
whity.

[3D SYNC OUTPUT DELAY]

Adjust the delay time if opening and closing timing of 3D eyewear shutter is not matched to the images. (when using VESA standard 3D
eyewear)
1)
Press as to select [3D SYNC OUTPUT DELAY].
2)
Press qw to adjust [3D SYNC OUTPUT DELAY].
Operation
Press the q or w button.
Note
f When [3D MODE] is set to [DLP Link] or [OFF], [3D SYNC OUTPUT DELAY] cannot be adjusted.
f Before adjusting [3D SYNC OUTPUT DELAY], display 3D images.

[LEFT/RIGHT SWAP]

Display images by inverting the timing of horizontal image switching. Change the settings when there is something wrong with the 3D image
being viewed.
When using 3D eyewear that supports DLP Link
1)
Press as to select [DLP Link].
2)
Press qw to switch [DLP Link].
f The items will switch each time you press the button.
[NORMAL]
[SWAPPED]
64 - ENGLISH
Chapter 4 Settings — [3D SETTINGS] menu
Select this when viewing 3D images using 3D eyewear that supports DLP Link.
Select this when viewing 3D images using VESA standard 3D eyewear.
Select this when viewing 3D images using both 3D eyewear that supports DLP Link and VESA
standard 3D eyewear.
Disables the control of 3D eyewear.
Adjustment
Changes in increments of 10 us.
Do not change the [NORMAL] setting if the 3D images are displayed correctly.
Select this when left and right 3D images are swapped to be displayed.
Range of adjustment
0 us - 25 000 us