Download Print this page

Furuno BT-5 Operator's Manual

Furuno bt-5 depth& fish finder: operators manual

Advertisement

Quick Links

BOOSTER BOX BT-5 OPERATOR'S MANUAL
The Booster Box BT-5 boosts the output power of the FCV-1200L from 3 kW to 5 kW.
Standard supply
BT-5 is available in two types: single frequency and dual frequency. Refer to the Packing
List supplied with this product for details.
Available transducers
5 kW: 28F-38M, 50F-38, 10 kW: 28F-72, 50F-70
Refer to the transducer installation drawings for the transducer, thru-hull pipe and tank.
Note: 10 kW transducer can not output the maximum 10 kW power. Maximum output is
about 5 kW.
Mounting and connection
Compass safe distance: Standard, 0.9 m, Steering, 0.5 m
Choose 5 kW transducer in the initial settings of the echo sounder. For the 10 kW
transducers, set 28F-72 as "28F-38M" and 50F-70 as "50F-38."
NCS-2RNCTSB 3 m
Attach frequency
labels here.
240
NCS-2RNCTSB 3 m
*1= Do not connect drain wires to GND on terminals.
Use the screws provided on the chassis.
Note: For single frequency type, connect 28 kHz to
"low frequency"; 50 kHz to "high frequency."
P U B . N o . O M C - 2 0 2 8 0 - A
B T - 5
( T E N I , 0 2 0 8 )
WARNING
ELECTRICAL SHOCK HAZARD
Do not open the equipment
unless totally familiar with
electrical circuits and
service manual.
Only qualified personnel
should work inside the
equipment.
4- 6
Tapping screw
High frequency side
TB1
HOT
Red
*1
Black
COLD
Yel
GND
GND
Yel
HOT
Red
*1
Black
COLD
TB1
Low frequency side
290
WARNING
Turn off associated echo
sounder before beginning
the installation.
Electrical shock may result
if it is not turned off.
Note: Tighten glands securely by hand.
TB2
Black
COLD
GND
Shield
Red
HOT
COLD
Black
GND
Shield
HOT
Red
TB2
Connect vinyl wire
for grounding.
Attach frequency labels here.

Advertisement

loading

Summary of Contents for Furuno BT-5

  • Page 1 BOOSTER BOX BT-5 OPERATOR’S MANUAL The Booster Box BT-5 boosts the output power of the FCV-1200L from 3 kW to 5 kW. WARNING ELECTRICAL SHOCK HAZARD Do not open the equipment unless totally familiar with electrical circuits and service manual.
  • Page 2: Environmental Condition

    However, output power of 10kW transducer is 5 kW or less. GENERAL Frequency Output Power ENVIRONMENTAL CONDITION Ambient Temperature Relative Humidity Waterproof Vibration COATING COLOR BT-5 28.8/50 kHz 5 kW -15° C to +55° C 95% at 40° C IPX2 IEC 60945 2.5GY5/1.5 SP - 1 E2028S01A...
  • Page 3 PACKING LIST PACKING LIST PACKING LIST PACKING LIST BT-5-1 BT-5-1 BT-5-1 BT-5-1 N A M E ユニット ユニット UNIT UNIT ユニット ユニット UNIT UNIT ブースターボックス BOOSTER BOX 工事材料 工事材料 INSTALLATION MATERIALS INSTALLATION MATERIALS 工事材料 工事材料 INSTALLATION MATERIALS INSTALLATION MATERIALS +トラスタッピンネジ 1種 TAPPING SCREW 周波数マーク FREQUENCY LABEL ビニール線...
  • Page 4 PACKING LIST PACKING LIST PACKING LIST PACKING LIST BT-5-2 BT-5-2 BT-5-2 BT-5-2 N A M E ユニット ユニット UNIT UNIT ユニット ユニット UNIT UNIT ブースターボックス BOOSTER BOX 工事材料 工事材料 INSTALLATION MATERIALS INSTALLATION MATERIALS 工事材料 工事材料 INSTALLATION MATERIALS INSTALLATION MATERIALS +トラスタッピンネジ 1種 TAPPING SCREW 周波数マーク FREQUENCY LABEL ビニール線...

This manual is also suitable for:

Booster box bt-5