Troubleshooting - Graco Ultra Operation, Parts

Cordless airless handhelds
Hide thumbs Also See for Ultra:
Table of Contents

Advertisement

Troubleshooting

Troubleshooting
Check everything in this Troubleshooting
Table before you bring the sprayer to an
authorized service center.
Sprayer Diagnostics
Problem
Sprayer makes no sound
when trigger is pulled
30
Cause
Diagnostic light blinks two times
when trigger is pulled. Indicates
incorrect voltage.
Diagnostic light blinks three times
when trigger is pulled. Indicates
battery temperature is too hot or cold.
Diagnostic light blinks four times
when trigger is pulled. Indicates
locked rotor condition.
Diagnostic light does not blink when
trigger is pulled. Indicates battery is
not installed or is damaged.
844-241-9499
Solution
Replace battery with a charged
battery.
Battery has reached end of life.
Replace the battery.
Allow battery to cool down or
warm up to room temperature.
Replace pump and/or motor
assembly.
Install battery or replace battery.
Replace Smartcontrol.
3A4476E

Advertisement

Table of Contents
loading

This manual is also suitable for:

UltimateTc pro17n16417p51517p51617n165 ... Show all

Table of Contents