Gas Supply Line
Provide a gas supply line of 3/4" (19 mm) rigid pipe to the
cooktop location. A smaller size pipe on longer runs may
result in insufficient gas supply. Pipe-joint compounds that
resist the action of propane gas must be used. Do not use
TEFLON
tape. With propane gas, piping or tubing size can
®†
be 1/2" (13 mm) minimum. Usually, Propane gas suppliers
determine the size and materials used in the system.
Flexible metal appliance connector:
If local codes permit, use a 5/8" (16 mm) flexible stainless
steel tubing gas connector, designed by CSA to connect
the cooktop to the rigid gas supply line.
A
/
" (13 mm) male pipe thread is needed for connection
1
2
to the female pipe threads of the inlet to the appliance
pressure regulator.
Do not kink or damage the flexible metal tubing when
moving the cooktop.
Must include a shut-off valve:
Install a manual gas line shut-off valve in an easily accessible
location. Do not block access to shut-off valve. The valve is
for turning on or shutting off gas to the cooktop.
B
A
A. Gas supply line
B. Shut-off valve open position
C. To cooktop
TEFLON is a registered trademark of Chemours.
®
6
The gas pressure regulator supplied with this cooktop must be
used. The inlet pressure to the regulator should be as follows for
proper operation:
Natural Gas:
Minimum pressure: 6" (15.2 cm) WCP
Maximum pressure: 14" (35.5 cm) WCP
Propane Gas:
Minimum pressure: 11" (27.9 cm) WCP
Maximum pressure: 14" (35.5 cm) WCP
Contact local gas supplier if you are not sure about the
inlet pressure.
Input ratings shown on the model/serial/rating plate are for
elevations up to 2,000 ft (609.6 m).
For elevations above 2,000 ft (609.6 m), ratings are reduced
at a rate of 4% for each 1,000 ft (304.8 m) above sea level
(not applicable for Canada).
For elevations above 6,560 ft (1999.5 m) a high altitude kit
is needed to avoid any reduced power output. See separate
propane gas conversion instructions sheet.
Line pressure testing above
[14" (35.6 cm) WCP]
The appliance and its individual shut-off valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
1
C
Line pressure testing at
[14" (35.6 cm) WCP] or lower
The appliance must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than
Gas Pressure Regulator
Burner Input Requirements
Gas Supply Pressure Testing
/
 psi (3.5 kPa).
2
/
1
2
/
psi (3.5 kPa) gauge
1
2
psi (3.5 kPa) gauge
/
psi (3.5 kPa).
1
2