Remote Console Interconnections Via A 4-Wire Modem - Ericsson LBI-39055A Maintenance Manual

C3 maestro console system
Table of Contents

Advertisement

LBI-39055
FDX Jumper
SLOT 8 Jumper
-BIAS and +BIAS
Configuration for the 3PXOCC1A board is:
Address Switches (S1)
Interrupt Jumper
Jumpers JP12 − JP15
Jumpers JP16 − JP17
If any other RS-422 plug-in serial board is used the
following board configuration must be used:
COM Port
Port Address
Interrupt
See Figure 8A or the manufacturer's documentation for
COM port connector pin-out details. As required,
interconnect the control data connections between the PC
and the appropriate CEC/IMC Data Concentrator Card or
the
respective
punch
recommended.
In some cases, the console equipment package is
equipped with a factory pre-wired 100-foot control data
cable. This cable has a female DB-25 connector on one end
for mating to the RS-422 plug-in serial board's male DB-25
connector. The other end is "pig-tailed" (unterminated) so
the wires may be punched down to the appropriate terminals
on the CEC's/IMC's punch block. If utilizing the pre-wired
cable, see the Cable Assembly Diagram near the end of this
manual for wire color coding.

Remote Console Interconnections Via A 4-Wire Modem

When the C3 Maestro is installed at a remote location
from the CEC/IMC, serial control data must be routed via
RS-232 connections and 4-wire modems. Since the C3
Maestro requires a dedicated or continuous serial link (non-
dial-up), a 4-wire leased line (or equivalent) meeting 3002
data grade specifications must be employed between the
CEC/IMC and the C3 Maestro in a remote console
installation.
Figure 8B shows typical control data interconnections
for a remote console installation using RS-232 connections
and full-duplex 4-wire modems. At the CEC/IMC Data
Concentrator Card, RS-232 connections are made at J13, not
J12. Observe all notes listed in the figure if wiring an
installation of this type. Recommended modem settings are:
8
In
Out (RS422AT-P)
Out (RS422I-P)
All Off
IRQ4
Upper Position
Lower Position
COM1
3F8
IRQ4
block.
Shielded
pairs
• •
Modem Options
DCE Rate = 9600
Originate/Answer = Originate (CEC/IMC modem)
Originate/Answer = Answer (C3 Maestro modem)
V.32 Fast Train = Enabled
Auto Retrain = Enabled
Internal/External Clock = Internal
Dial-Up/Leased Line = Leased
2-Wire/4-Wire = 4 Wire
TX Level = (as required; use -15 dBm if line loss is 0 dB)
Dial Backup = Manual
Loop Back Time = 15 minutes
Dial Line = RJ11
Line Current Disconnect = Long
Long Space Disconnect = Enabled
V.22 Guard Tone = Disabled
are
• •
MNP Options
MNP Protocol = Enabled
Auto Fallback = Enabled (or Normal)
Flow Control = CTS Only
XON/XOFF Pass Through = Enabled
Data Compression = Disabled
Inactivity Timer = Off
Break Control = 5
• •
DTE Options
Synchronous/Asynchronous Data = Asynchronous
DTE Rate = 9600
Character Length = 8 Bits
Parity = None
Commanded Dialer = Asynchronous
AT Command Set = Disabled
DTR Control = Disabled
DSR = Forced High
DCD = Normal
CTS = Forced High
DTE Fallback = Disabled
Options = Retained At Disconnect