DRT3500 Series Direct-Vent Gas Fireplaces
Installing the Backup Batteries
With a battery backup, electronic fireplaces can automatically switch to battery power. In the event of a power outage, this
allows ON/OFF operation (without blower functionality). Install new batteries before every burn season.
1. Open the lower control panel, and locate the battery holder (see Figure 39).
2. Install four (4) AA batteries in the battery holder.
3. Close the lower control panel.
Figure 39 - Battery Holder (in control compartment)
Figure 40 - Switches (in control compartment)
Continuous Pilot Ignition Switch
Fireplaces with an electronic gas valve have a continuous pilot ignition (CPI) controlled by the remote
This switch allows the pilot to be switched from intermittent mode to continuous mode:
Intermittent Mode—The pilot is extinguished when the fireplace is OFF.
Continuous Mode—The pilot stays ON when the fireplace is OFF.
In periods of extreme cold, condensation may form on the glass door when the fireplace is OFF and the pilot is in
intermittent mode. Also, with the pilot in intermittent mode, the fireplace may cycle startup (i.e., the pilot and burner ignite,
but the burner extinguishes and reignites several times until the flue reaches the temperature for proper drafting).
To save energy—switch to intermittent mode.
For a standing pilot that will help prevent glass door condensation and cycle startup—switch to continuous mode.
NOTE: Continuous mode is indicated by a pilot that comes ON and remains lit when the fireplace is OFF.
Traditional Only: Installing the Firebox Liners
1. Remove the three (3) optional firebox liner panels from the packing materials if purchased.
2. Carefully position the rear panel, upper edge first, in the firebox against the rear wall.
3. While holding the rear panel, carefully position the left side panel in the firebox.
4. Carefully position the right side panel in the firebox.
NOTE: Do not force the panels. Excessive force may cause breakage. If the panels are correctly positioned, they will
fit snugly in place.
Some parts have been removed for clarity
Learn Switch is for programming the remote (see
instructions provided with the remote control)
IPI Switch is for continuous pilot or standing pilot
Hi-Low Switch controls the main burner flame height
ON/OFF Switch turns the burner on and off
Operation