13  Technical Data

13.3 General Data

Width x height x depth, inverter
Width x height x depth, DC Disconnect
Weight inverter
Weight DC Disconnect
Length x width x height of the inverter packaging
Length x width x height of the DC Disconnect
packaging
Transport weight inverter
Transport weight DC Disconnect
Climatic category according to IEC 60721-3-4
Operating temperature range
Maximum permissible value for relative humidity,
non-condensing
Maximum operating altitude above
Mean Sea Level
Noise emission, typical
Power loss in night mode
Topology
Cooling concept
Fan connection
Electronics degree of protection
Protection class
Overvoltage category
Approvals, as at September 2013
Grid configurations
* Sunny Boy 6000TL-US, 7000TL-US and 7700TL-US: − 22°F to +140°F ( − 30°C to +60°C)
90
SB3-5TLUS22-IA-en-16
5
19
in. x 20
16
(490 mm x 519 mm x 185 mm)
13
7
in. x 11
32
(187 mm x 297 mm x 190 mm)
52.9 lb (24 kg)
4.4 lb (2 kg)
5
24
in. x 23
16
(617 mm x 597 mm x 266 mm)
39
14
in. x 9
64
(370 mm x 240 mm x 280 mm)
59.5 lb (27 kg)
6.6 lb (3 kg)
4K4H
− 40°F to +140°F ( − 40°C to +60°C)*
100%
3,000 m
≤ 25 dB(A)
< 1 W
Transformerless
Convection
designed for safe disconnection in accordance
with DIN EN 50178:1998-04
(until 2013 replaced by DIN EN 62109-1)
NEMA 3R
UL 1741,
UL 1699B,
IEEE 929-2000,
IEEE 1547,
Canadian Electrical Code
CSA C22.2 N0. 107.1-01
208/120 V Wye,
120/240 V Split-phase
SMA America, LLC
1
5
in. x 7
in.
2
16
45
1
in. x 7
in.
64
2
1
1
in. x 10
in.
2
2
13
in. x 11 in.
32
I
IV
®