13 Technical Data
Displacement power factor cos φ, adjustable
Feed-in phases
Phase connection
Surge category in accordance with
IEC 60664-1
* According to VDE-AR-N 4105, the rated power at 230 V, 50 Hz of the SB5.0-1AV-41 is 4600 W
** According to VDE-AR-N 4105, the rated power at 230 V, 50 Hz of the SB5.0-1AV-41 is 4600 VA
*** Depending on the configured country data set
**** According to AS 4777, the maximum output current is 21.7 A
Efficiency
Maximum efficiency, η
European weighted efficiency, η

13.2 General Data

Width x height x depth
Weight
Length x width x height of the packaging
Transport weight
Climatic category in accordance with
IEC 60721-3-4
Environmental category
Pollution degree outside the enclosure
Pollution degree inside the enclosure
Operating temperature range
Maximum permissible value for relative humidity
(condensing)
Maximum operating altitude above mean sea
level (MSL)
Typical noise emission
Power loss in night mode
Maximum data volume per inverter with Speed-
wire/Webconnect
104
SBxx-1AV-41-BE-en-12
max
EU
SB5.0-1AV-41
0.8 overexcited to 1 to
0.8 underexcited
1
1
III
SB5.0-1AV-41
97.0 %
96.5 %
435 mm x 470 mm x 176 mm
495 mm x 595 mm x 250 mm
20.5 kg
Outdoors
-25°C to +60°C
3000 m
25 dB(A)
550 MB/month
SMA Solar Technology AG
SB6.0-1AV-41
0.8 overexcited to 0.8
underexcited
1
1
III
SB6.0-1AV-41
97.0 %
96.5 %
16 kg
4K4H
3
2
100 %
5 W
Operating manual