1-3 Precautions for the Safety

 Do not pull any electric wires and do not touch an auxiliary power switch with a wet hand.
– There is a danger of electric shock or fire.
 In case any wire or power plug has been damaged, replace it to eliminate any possible danger.
 Do not bend the power cord by force and do not put any heavy object on the power cord.
– There is a danger of electric shock or fire.
 Do not use multi socket.
– There is a danger of electric shock or fire.
 Ground the product if necessary.
– Be sure to ground the product if there is any danger of electric leakage due to water or moisture.
 Be sure to turn off the auxiliary power switch or pull out the power plug during replacement or repair of elec-
tric parts.
– There is a danger of electric shock.
 In case the product will not be in use for a long time, the battery of remote control should be kept separately.
– Leakage of inside fluid can cause break down of remote control.

1-4 Others

 Never store or load the air conditioner upside down or sideways to prevent the damage to the compressor.
 Young children or infirm persons should be always supervised when they use the air conditioner.
 Max current is measured according to IEC standard for safety.
 Current is measured according to ISO standard for energy efficiency.
 When installing, make sure there is no leakage. When recovering the refrigerant, ground the compressor first before
removing the connection pipe. If the refrigerant pipe is not properly connected and the compressor works with the
service valve open, the pipe inhales the air and it makes the pressure inside of the refrigerant cycle abnormally high.
It may cause explosion and injury.
 Pump Down Procedure (When removing the product)
- Turn on the air conditioner and select Cool mode to run the compressor for 3 minutes.
- Release the valve caps on High and Low pressure side.
- Use L wrench to close the valve on the high pressure side.
- Approximately 2 minutes after, close the valve on the low pressure side.
- Stop operation of the air conditioner.
- Disconnect the pipes.