Contents 11. Precautions ............................1-1 Precautions for the Service ......................................1-2 Precautions related to static electricity and PL 1-3 Precautions related to product safety ................... 1-4 Other precautions ..........................12. Product Specifications ..............................................2-1 The Feature of Product 2-2 Product Specifications ........................
Page 3
4-4-9 O.C(Over Current) error ........................4-29 4-4-10 DC_link voltage sensor error ......................4-30 4-4-11 DC_link voltage under/over error, Over voltage protection error/PFC over load ..4-31 4-4-12 DC_link voltage sensor error ......................4-32 4-4-13 Current sensor error/Input current sensor error ..............4-33 4-4-14 Heatsink sensor error/Heatsink over heat .................
Check whether the installation location is at least two meters away from other electronic products such as TV, video, or audio. – Otherwise, the video quality might be degraded or noise might be generated. Do not let end users repair the products themselves. – Unauthorized disassembly might cause electric shock or fire. Samsung Electronics...
– Release the high pressure and low pressure valve caps. – Close the high pressure valve completely using an L-wrench – After about two minutes, close the low pressure valve completely. – Stop running the air conditioner. – Separate the connecting pipe. Samsung Electronics...
With the advanced BLDC inverter technology, it makes a room cool with highly energy saving and arises the efficiency of air conditioner. Long Ambient Operation(In Low Temperature) It can arise the reliability and the capacity of the air conditioner, especially operated in low temperature. Eco-friendly Product(Lead-Free, ROHS, WEEE) Easy installation of ultra-lightweight indoor unit Samsung Electronics...
2-2 Product Specifications AC026KNADEH/EU AC035KNADEH/EU ITEM AC026JXSCEH/EU AC035JXSCEH/EU Indoor Unit Outdoor Unit IMAGE Remote Controller Power Product 1Φ, 220-240V/50Hz 1Φ, 220-240V/50Hz Indoor L x H x D 896*261*261 896*261*261 Outdoor L x H x D 790*285*548 790*285*548 Indoor Product kg(Net) 11.0...
Page 8
51/51 Noise blow (Cooling/ In case of strongest air Heating) Outdoor unit 58/60 blow Refrigerant (R410A) 2900 Liquid 9.52 Connecting Pipe 15.88 Additional Refrigerant (R410A) Standard Extension length(Total) Extension length(Elevation) Product 01026C-19547F-274750-371700 Option Option Code Installation 020000-100000-200100-300000 Option Samsung Electronics...
3-1 Indoor unit AC026KNADEH / AC035KNADEH / AC071KNADEH Parts Procedure Remark PANEL-FRONT 1) Stop the driving of air conditioner and shut off main power supply. 2) Detach FILTER PRE from the PANEL FRONT. 3) Cover Panel is assembled on bottom of indoor unit as shown in the figure.
Page 12
5) Separate the hook after pushing both end of Cover Panel as shown in the figure. (Watch out for the damage of the hook) 6) Raise front part upward obliquely as shown in the figure and then remove the hooks. Samsung Electronics...
Page 13
Assembly of Cover Panel after service end. - Reassembly is in the reverse order of the removal. - Piping and drain hose must be careful not to damage and Progress must be done with both hands. Hook (Side) Hook (Center) Screw Cap Screw Samsung Electronics...
Page 14
4 HOOK Structures. When separate the hook : Use the (-) screw Driver. (-)Screw Driver Insert the hook and then pull the hook as shown on the right side. (Watch out for the damage of the hook) Samsung Electronics...
Page 15
Parts Procedure Remark 9) Remove the Panel Frame from the Main Frame as shown on the right side. Samsung Electronics...
Page 16
2) Lossen Stepping Motor, EEV, Display, Sensor, SPI, Fuse Wire. Caution: When you separate the connector, pull pressing the locking button. 3) Lossen Motor, Terminal Wire. Caution: When you separate the connector, pull pressing the locking button. 4) Loosen Earth Wire. Samsung Electronics...
Page 17
9) Take off the CASE-CONTROL from the main frame after loosen the remaining connector. Caution: When you separate the connector, pull pressing the locking button. TRAY DRAIN 1) To detach TRAY-DRAIN from the main frame, pull the bottom of the TRAY-DRAIN towards you. Samsung Electronics...
Page 18
2) Unfasten the screw at the left side. (use + Screw Driver) 3) Unfasten the screw at the right side. (use + Screw Driver) 4) To detach Evaporator from the main frame, pull the bottom of the Evaporator towards you. Samsung Electronics...
Page 19
FAN MOTOR 1) Unfasten the screw. (use + Screw Driver) & CROSS FAN 2) Detach the FAN Motor case. 3) Unfasten the screw a little. (use + Screw Driver) 4) Pull the CROSS-FAN to the left side. 3-10 Samsung Electronics...
1) Loosen 1 pcs screw of cover control,and detach it. 2) Loosen 5 pcs screws on both right and left cabinet side edges and to detach the cover-top 3) Loosen 7 screws fixed to disassemble cabi-front , and detach it. Samsung Electronics 3-11...
Page 21
Parts Procedure Remark common work 4) Loosen 7 screws to disassemble the cabi- right ,and detach it. 5) Loosen 2 screws to disassemble steel-bar. 6) Loosen 3 screws to disassemble cabi-left. 3-12 Samsung Electronics...
Page 22
Remark fan&motor 1) Loosen 1 screw as indication and detached the fan. 2) Loosen 4 pcs motor screws and disconnect the wire between assy control out and motor. 3) Loosen 2 pcs bracket-motor screw and detach it. Samsung Electronics 3-13...
Page 23
Heat exchanger 1) Release the refrigerant at first 2) Loosen fixing screw on both side. 3) Disassemble the pipes in both inlet and outlet with welding torch. 4) Detach the heat exchanger. 3-14 Samsung Electronics...
Page 24
Parts Procedure Remark compressor 1) Disconnect the compressor lead wire . 2)Disassembly the felt comp sound. loosen the 3 bolts at the bottom of compres sor. Samsung Electronics 3-15...
Page 25
Cabi Install Front 1) Unscrew and remove 1 screw in the Cabinet-Install Front. (Use +Screw Driver) Guard Cond 1) Pull the sensor from Guard Cond. 2) Unscrew and remove 4 screws in the Guard Cond. (Use +Screw Driver) 3-16 Samsung Electronics...
Page 26
Cabinet Back RH. (Use +Screw Driver) Cabi Install Back 1) Unscrew and remove 1 screw in the Cabinet-Install Back. (Use +Screw Driver) Cabi Front LF 1) Unscrew and remove 10 screws in the Cabinet-Front LF. (Use +Screw Driver) Samsung Electronics 3-17...
Page 27
2) Remove the Cover from the Fan Propeller 3) Turn 2 mounting nuts as shown in the picture and remove it. (Use Adjustable Wrench) When you assemble the Fan Propeller and the Cover, must check the rib in the hole. 3-18 Samsung Electronics...
Page 28
1) Unscrew and remove 2 mounting screws in Bracket Motor. (Use +Screw Driver) Heater 1) Unscrew and remove 4 screws on the Base Out. (Use +Screw Driver) 2) Disconnect the heater wire from the Ass'y Control Out. Samsung Electronics 3-19...
Page 29
Coolant inside the Compressor completely and remove the pipe with a welding flame. Assy EEV Valve 1) Unscrew and remove 2 mounting screws in Service Valve. (Use +Screw Driver) 2) Separate the pipe from the Entrance/ Exit using a welder. 3-20 Samsung Electronics...
For example : SEG2, 3 SEG4, 5 SEG6, 8 SEG9, 10 SEG11, 12 SEG 14, 15 SEG 16, 17 SEG 18, 20 SEG 21, 22 SEG23, SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 On(SEG1~12) Off (SEG13~24) SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 SEG19 SEG20 SEG21 SEG22 SEG23 SEG24 Samsung Electronics...
Page 31
Press Mode button to be changed to AUTO mode in the OFF status. 11. Setting SEG14, SEG15 option Press Low Fan button(∨) to enter SEG14 value. Press High Fan button(∧) to enter SEG15 value. Each time you press the button, … will be selected in rotation. SEG14 SEG15 Samsung Electronics...
Page 32
Step 5. Check operation 1. Reset the indoor unit by pressing the RESET button of indoor unit or outdoor unit. 2. Take the batteries out of the remote controller and insert them again and then press the operation button. Samsung Electronics...
Page 33
Example) If you want to set as "MAIN : 3, CHANNEL : 1, RMC : B", SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 assign option codes except SEG 1, 7 which are page options. Samsung Electronics...
Page 34
S-Plasma ion Buzzer control external control filter Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details Disuse Thermo on Disuse 1000 Hour ON/OFF Indication Control and Details Operation OFF Control 2000 Hour Disuse WINDOW Control Samsung Electronics...
SEG3 SEG4 SEG5 SEG6 The tens’ digit of an The unit digit of an The option mode Explanation PAGE MODE option SEG you will option SEG you will The changed value you want to change change change Indication Samsung Electronics...
Page 37
14. Simultaneous opening of cooling/heating MCU SOL valve E180 (1st detection) 15. Simultaneous opening of cooling/heating MCU SOL valve E181 (2nd detection) Other outdoor unit self-diagnosis error that is not on the above list EEPROM error E162 EEPROM option error E163 Samsung Electronics...
PFC Overload Error Check Outdoor Inverter PBA E500 IPM is over heated. Check Outdoor Inverter PBA E554 GAS Leak error Check indoor and outdoor unit model E556 Capacity miss match between indoor and outdoor Check indoor and outdoor unit model Samsung Electronics...
In this case, is the resistance 8.300 value out of range in the temperature table on the right? 10.00 12.10 Indoor temperature sensor 14.70 failure (replace) 18.00 Restart the system after replacing the PCB 22.00 28.30 33.90 42.30 4-10 Samsung Electronics...
Page 40
In this case, is the resistance 8.300 value out of range in the temperature table on the right? 10.00 12.10 Failure of the indoor heat 14.70 exchanger temperature sensor (replace) 18.00 Restart the system after replacing the PCB 22.00 28.30 33.90 42.30 Samsung Electronics 4-11...
Page 41
PCB? Connect the connector to PCB and restart the unit Is there foreign substance stuck in the motor fan? Remove the foreign substance and restart the unit Replace the PCB and restart the unit 4-12 Samsung Electronics...
Page 42
PCB and replace the PCB Reconnect the cable connecting the outdoor unit to the indoor unit and restart the unit. If the communication still doesn’t work, replace the indoor unit PCB. Good +0.7V -0.7V Samsung Electronics 4-13...
Page 43
Is the terminal voltage around AC 220V? Is the water level in drain pan decreasing? Replace the drain pump Replace the indoor unit PCB Normal operation • F loatsensorerrorisclearedonly Replace the drain pump when the indoor power is reset 4-14 Samsung Electronics...
Page 44
EEPROM component failure, EEPROM circuit parts missing/damaged/soldering failure Are the EEPROM circuit components in good conditions? (missing components / damage / soldering failure) Replace the PCB if the restart fails Restart the unit after replacing the PCB Samsung Electronics 4-15...
Page 45
Is the voltage between Replace the inverter PBA the terminal 2 (~) and 4 (~) of the bridge diode 220V? Is the fuse connected? Replace the fuse Replace the inverter PBA Is the resistance value of R001 200Ω? Cont. 4-16 Samsung Electronics...
Page 46
Outdoor unit is not powered on – Initial diagnosis (cont.) Cont. Is the reactor connector Connect the reactor connected correctly? Replace the PBA. Samsung Electronics 4-17...
Is the power is normal? Exchange the PBA of no power unit (check the LED Lamp Exchange the indoor unit PBA. Terminate the service. Is the communication error occurred again? Exchange the outdoor unit PBA. 4-18 Samsung Electronics...
Connect the sensor to PBA connector (6pin) supply power and measure the voltage of #1-#2 in the connector Exchange the PBA of no power unit Below 0.5V or Over 4.5V? Micom error or connector check Exchange the Outdoor PBA Samsung Electronics 4-19...
Page 49
Connect the sensor to PBA connector (4pin) supply power and measure the voltage of #1-#2 in the connector Exchange the PBA of no Ourdoor PBA Below 0.5V or Over 4.5V? Micom error or connector check Exchange the Outdoor PBA 4-20 Samsung Electronics...
40°C - 5.83kohm Connect the sensor to PBA connector (6pin) supply power and measure the voltage of #5-#6 in the connector Exchange the Outdoor PBA Below 0.5V or Over 4.5V? Micom error or connector check Exchange the Outdoor PBA Samsung Electronics 4-21...
Page 51
40°C - 5.83kohm Connect the sensor to PBA connector(4pin) supply power and measure the voltage of #3-#4 in the connector Exchange the Outdoor PBA Below 0.5V or Over 4.5V? Micom error or connector check Exchange the Outdoor PBA 4-22 Samsung Electronics...
40°C - 115kohm Connect the sensor to PBA connector (6pin) supply power and measure the voltage of #3-#4 in the connector Exchange the Outdoor PBA Below 0.5V or Over 4.5V? Micom error or connector check Exchange the Outdoor PBA Samsung Electronics 4-23...
Page 53
40°C - 115kohm Connect the sensor to PBA connector(4pin) supply power and measure the voltage of #3-#4 in the connector Exchange the Outdoor PBA Below 0.5V or Over 4.5V? Micom error or connector check Exchange the Outdoor PBA 4-24 Samsung Electronics...
Restart after power off Is the discharge over temperature sensor error Terminate the service appeared again? Download the EEPROM data Is the discharge over temperature sensor error Terminate the service appeared again? Exchange the Outdoor PBA Exchanged the Compressor Samsung Electronics 4-25...
Is the voltage of CN901 #3-#5 and #3-#6 with in Exchange the Outdoor PBA 1Vdc~15Vdc during the operation? PBA problem or Motor problem Change the PBA first and check the operation Exchange the Fan motor 4-26 Samsung Electronics...
Connect the comp wire normally Is the connection of compressor wire is normal? Download the EEPROM data Is the restart error occurred again? Terminate the service Is the compressor body and interphase Exchange the Outdoor PBA resistance insulated? Exchanged the Compressor Samsung Electronics 4-27...
Connect the comp wire normally Is the connection of compressor wire is normal? (PBA and Compressor) Is the restart error occurred again? Terminate the service Is the compressor body and interphase Exchange the Outdoor PBA resistance insulated? Exchanged the Compressor 4-28 Samsung Electronics...
Terminate the service occurred again? Correct the sensor position or exchange the Is the position of temperature sensor and sensor sensing value normal? Is the compressor body and interphase Exchange the Outdoor PBA resistance insulated? Exchanged the Compressor Samsung Electronics 4-29...
Normal range(280Vdc~320Vdc) Is the DC_link sensing voltage(R104 or R004) is normal in Exchange the Outdoor PBA operation mode? Normal range (0.2Vdc~2.8Vdc) Exchange the Outdoor PBA Is the reactor insulation damaged? Exchange the Reactor 4-30 Samsung Electronics...
Check the input power mode? Normal range(280Vdc~320Vdc) Is the DC_link sensing voltage(R104 or R004) is normal in Exchange the Outdoor PBA operation mode? Normal range (0.2Vdc~2.8Vdc) Exchange the Outdoor PBA Is the reactor insulation damaged? Exchange the Reactor Samsung Electronics 4-31...
Correct the sensor position or exchange the Is the position of temperature sensor and the sensing value sensor normal? Is the connection cable for the compressor and Correct the cable connection power terminal normal? Exchange the Outdoor PBA 4-32 Samsung Electronics...
3) Is there no short or open around IC451(PF2) or IC451,IC452(PF3)? 2. Troubleshooting procedure Restart after power off. Exchange the Outdoor PBA Is the PFC shunt and IPM shunt resistance value correct? Terminate the service Is the current sensor error appeared again? Exchange the Outdoor PBA Samsung Electronics 4-33...
4) Is the cover assembly in control-box normal? 2. Troubleshooting procedure Restart after power off. Fastening the screw Are there screws in PBA-heatsink? (4 screws) Check the fan connection Is the fan operation normal? Change the Fan motor Exchange the Outdoor PBA 4-34 Samsung Electronics...
Terminate the service again? Is the position of temperature sensor and Correct the sensor position or exchange the sensing value normal? sensor Is the compressor body and interphase Exchange the Outdoor PBA resistance insulated? Exchange the Outdoor PBA Samsung Electronics 4-35...
3) Did you download or insert EEPROM IC, after changing outdoor PBA? 2. Troubleshooting procedure power off and download EEPROM data (or. Insert the service EEPROM IC) Restart after power off Terminate the service Is the error appeared again? Exchange the Outdoor PBA 4-36 Samsung Electronics...
1) Check the power condition at customer's house (Is there any power noise?) 2) Have been there power failure? 2. Troubleshooting procedure Restart after power off Is the AC line zero cross signal error appeared Terminate the service again? Exchange the Outdoor PBA Samsung Electronics 4-37...
* Heating mode * * Cooling mode * Is the outdoor temperature over 40°C or under Is the outdoor temperature under °C? -30°C? The temperature condition is too poor to operate. Wait until temperature is changed 4-38 Samsung Electronics...
Reset the option code again at indoor unit Is the capacity miss match error appeared Terminate the service again? Download the EEPROM data Terminate the service Is the capacity miss match error appeared again? Exchange the Outdoor PBA Exchange the Indoor PBA Samsung Electronics 4-39...
Is the EEV valve is operation? Change the EEV valve Check the sound of EEV valve after power on. Check the pipe crack. Is the pressure of refrigerant normal? Fill up the refrigerant. Exchange the Indoor PBA Exchange the Outdoor PBA 4-40 Samsung Electronics...
5. PCB Diagram 5-1 PCB Diagram 5-1-1 Indoor Unit PCB (AC026KNADEH / AC035KNADEH / AC071KNADEH) Main PBA Samsung Electronics...
Page 71
#1~2 : COMMUNICATION SIGNAL #3~4 : SUB PBA SIGNAL #5 : EXTERNAL CONTROL SIGNAL #6 : COMP CHECK SIGNAL #7 : ERROR CHECK SIGNAL #8 : DC 5V #9 : GND #10 : DC 12V #11~14 : COMMUNICATION SIGNAL Samsung Electronics...
Page 72
■ Sub PCB ① CN1-2WIRES COMM. #1,#2,#19,#20:COMM. SIGNAL #3,#18:EXTERNAL CONTROL #4,#17:COMP CHECK #5,#16:ERROR CHECK #6:VCC(DC5V) #7,#14:GND #8,#13,#15:DC12V #9~#12:COMM. SIGNAL Samsung Electronics...
SUB PBA POWER:SMW200-05P BLK EEVA:SMW250-05 RED COMP:DBT061-3P WHT SMPS: SMW250-03 BLU EEPROM:B7P-MQ WHT TEMP SENSOR: SMW200-08P WHT MAIN DOWNLOAD:YDW200-20 BLK SUB PBA: SMW200-10P BLK DRED:SMW250-05 WHT INV DOWNDOWN: YDAW200-20TR BLK SUB PBA: SMW200-10P WHT ENABLE CGND: SMW250-03 RED EEVB/SUB PBA:SMW250-05 YEL Samsung Electronics...
Page 74
SMW250-06 WHT 3711-000939 CN801 ERROR/COMP CHECK SMW250-04 RED 3711-000176 CN12 DC12V YW396-02V BLU 3711-000997 CN803 EEV1 SMW250-05 BLU 3711-001036 CN802 EEV4 SMW250-06 BLU 3711-001084 CN403 OUT TEMP/COND/DISQ/OLP SMW250-08 WHT This Document can not be used without Samsung’s authorization. Samsung Electronics...
Page 75
#3 : COMP. U-phase(YEL) #4 : DC 15V #4 : DC 15V #5 : FAN RPM #5 : FAN RPM #6 : FAN RPM feedback #6 : FAN RPM feedback This Document can not be used without Samsung’s authorization. Samsung Electronics...
Page 76
EMI PCB ① ② ③ L1-AC POWER L phase N1-AC POWER N phase CN01-AC POWER L1 : BRN N1 : SKY-BLU #1-#3 : AC 220~240V This Document can not be used without Samsung’s authorization. Samsung Electronics...
Operating Instructions and Installation 6. Wiring Diagram 6-1 Indoor Unit This Document can not be used without Samsung’s authorization. Samsung Electronics...
PACK MULTI RAC-Vivace AIR HANDIING UNIT DVM HOME AIR HANDLING UNIT SINGLE HYDRO UNIT MULTI ※ "/" can be removed from the buyer card if there are not enough digits. HYDRO UNIT MONO HYDRO UNIT WATER TANK FLAT STAND Samsung Electronics...
You can open the valve by turning the need valve counterclockwise using hex wrench, and it is used for vacuum, gas purging, coolant injection, coolant purging, and indoor-outdoor unit connection. ■ ACCUMULATOR Accumulator prevents the flow of liquid-state coolant into the compressor. (Liquid-state coolant flowing into the compressor will overload the compressor.) Samsung Electronics...