Electrostatic Discharge Requirements; Reliability; Electrical And Optical Characteristics And Performance; Main Power Supply - Acer X163W Service Manual

Hide thumbs Also See for X163W:
Table of Contents

Advertisement

Acer
2.3

Electrostatic Discharge Requirements

Item
Electrostatic Discharge
2.4

Reliability

Items
MTBF
CCFL Life time
.
Note1
Display an all WHITE field at mid Brightness and Contrast settings.

3. Electrical and Optical Characteristics and Performance

3.1 Main Power Supply

Items
AC Input Voltage Range
AC Input Current
AC Frequency Range
Inrush Current
Regulator Efficiency
Ripple and Noise
DC Output Voltage and Current
Power consumption
Protection
Power management
Table-1
Protection
SCP(short circuit protection)
OPP(Over power protection)
Table-2
Status
Power On
Power Saving
Condition
IEC61000-4-2(EN55024)
Condition
Luminance becomes 50%
Condition
Universal input full range
100Vac
240Vac
100Vac
240Vac
100Vac,cold star,25°C
240Vac,cold star,25°C
DC output full loading
+14.2V output
+5V output
VCC14.2V(13.5~16.3V)
VCC5.2V(4.95~5.45V)
without Audio
Condition
Short output (for 5V
output it must be shorted
before F802)
nominal AC input
H-sy
V-sy
Video
nc
nc
on
on
active
off
on
blanked
on
off
blanked
Spec
Contact discharge : 4KV
Contact discharge : 8KV
Air discharge : 8KV
Air discharge : 15KV
Spec
≧ 40,000 Hours
≧ 40,000 Hours(min)
Spec
100~240VAC /50~60Hz
0.8A(max)
0.4A(max)
50Hz – 60Hz
40A (max)
60A(max)
≥75%
<500mv
<150mv
1.1A(typ.),1.4A(max)
0.8A(typ.),1.0A(max)
≤25W
Spec
with auto-recovery function
32W ( min )
Power
≤ 25W
Blue
< 2W
Orange
< 2W
Orange
5
Acer –LCD-X163W
Note
Excluding the
LCD, CCFL
Note1
Note
See Table-1
See Table-2
LED

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents