Gigabyte G492-Z51 User Manual

Gigabyte G492-Z51 User Manual

Hpc server - 4u dp 10 x gen4 gpu server
Hide thumbs Also See for G492-Z51:
Table of Contents

Advertisement

Quick Links

G492-Z51
HPC Server - 4U DP 10 x Gen4 GPU Server
User Manual
Rev. 1.0

Advertisement

Table of Contents
loading

Summary of Contents for Gigabyte G492-Z51

  • Page 1 G492-Z51 HPC Server - 4U DP 10 x Gen4 GPU Server User Manual Rev. 1.0...
  • Page 2 GIGABYTE's prior written permission. Documentation Classifications In order to assist in the use of this product, GIGABYTE provides the following types of documentation:  User Manual: detailed information & steps about the installation, configuration and use of this product (e.g.
  • Page 3 Conventions The following conventions are used in this user's guide: NOTE! Gives bits and pieces of additional information related to the current topic. CAUTION! Gives precautionary measures to avoid possible hardware or software problems. WARNING! Alerts you to any damage that might result from doing or not doing specific actions.
  • Page 4 Server Warnings and Cautions Before installing a server, be sure that you understand the following warnings and cautions. WARNING! To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
  • Page 5 Electrostatic Discharge (ESD) CAUTION! ESD CAN DAMAGE DRIVES, BOARDS, AND OTHER PARTS. WE RECOMMEND THAT YOU PERFORM ALL PROCEDURES AT AN ESD WORKSTATION. IF ONE IS NOT AVAILABLE, PROVIDE SOME ESD PROTECTION BY WEARING AN ANTI-STATIC WRIST STRAP AT- TACHED TO CHASSIS GROUND -- ANY UNPAINTED METAL SURFACE -- ON YOUR SERVER WHEN HANDLING PARTS.
  • Page 6 CAUTION! Risk of explosion if battery is replaced incorrectly or with an incorrect type. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used bat- teries according to the manufacturer’s instructions.
  • Page 7: Table Of Contents

    Table of Contents Chapter 1 Hardware Installation ................... 11 Installation Precautions .................. 11 Product Specifications ..................12 System Block Diagram ................... 15 Chapter 2 System Appearance ..................17 Front View ...................... 17 Rear View ....................... 18 Front Panel Buttons and LEDs ............... 19 Front System LAN LEDs ................
  • Page 8 The Main Menu ....................51 Advanced Menu ..................... 54 5-2-1 Trusted Computing ....................55 5-2-2 PSP Firmware Versions ..................56 5-2-3 Legacy Video Select ....................57 5-2-4 AST2500 Super IO Configuration ................58 5-2-5 S5 RTC Wake Settings ...................60 5-2-6 Serial Port Console Redirection ................61 5-2-7 CPU Configuration ....................64 5-2-8...
  • Page 9 5-8-2 UEFI Application Boot Priorities ................115 Save & Exit Menu ..................116 5-10 BIOS POST Beep code (AMI standard) ............117 5-10-1 PEI Beep Codes ....................117 5-10-2 DXE Beep Codes ....................117 - 9 -...
  • Page 10 This page left intentionally blank - 10 -...
  • Page 11: Chapter 1 Hardware Installation

    Chapter 1 Hardware Installation Installation Precautions The motherboard/system contain numerous delicate electronic circuits and components which can become damaged as a result of electrostatic discharge (ESD). Prior to installation, carefully read the service guide and follow these procedures: • Prior to installation, do not remove or break motherboard S/N (Serial Number) sticker or warranty sticker provided by your dealer.
  • Page 12: Product Specifications

    Product Specifications NOTE: We reserve the right to make any changes to the product specifications and product-related informa- tion without prior notice. System Š Dimension 448 (W) x 176 (H) x 880 (D) (mm) Š 17.64 (W) x 6.93 (H) x 34.65 (D) (inch) Š...
  • Page 13 Expansion Slot 10 x PCIe x16 slots (Gen4 x16 bus) for GPUs ( Broadcom solution) Š 2 x PCIe x16 (Gen4 x16 bus) Half-length low-profile slot in front side Š 1 x PCIe x16 (Gen4 x16 bus) Half-length low-profile slot in rear side# Š...
  • Page 14 System Aspeed® AST2500 management controller Š Management GIGABYTE Management Console (AMI MegaRAC SP-X) web interface Š Dashboard Š JAVA Based Serial Over LAN Š HTML5 KVM Š Sensor Monitor (Voltage, RPM, Temperature, CPU Status …etc.) Š Sensor Reading History Data Š...
  • Page 15: System Block Diagram

    System Block Diagram 8-bay 3.5” NVMe/SATA hybrid + 4-bay 3.5” SATA CFPG015 10/100/1G MLAN PHY(1ch) (front side) ASPEED AST2500 (front side) 2 x 10GbE BASE-T LAN Intel (front side) X550-AT2 ASM1042 2 x USB 3.0 (front side) CPU0 CPU1 xGMI2 18GT/s X3 Link AMD MILAN AMD MILAN...
  • Page 16 This page intentionally left blank Hardware Installation - 16 -...
  • Page 17: Chapter 2 System Appearance

    Chapter 2 System Appearance Front View HDD #0 HDD #3 HDD #6 HDD #9 HDD #1 HDD #4 HDD #7 HDD #10 HDD #2 HDD #5 HDD #8 HDD #11 No. Description Description RAID Card Slot USB 3.0 Port x 2 Front Panel LEDs and Buttons VGA Port 10GbE LAN Port x 2...
  • Page 18: Rear View

    Rear View PSU #3 PSU #2 PSU #1 No. Description Description PCIe x16 Slot x 8 PCIe x16 Slot x 1 Power Supply Unit x 3 (PSU #1 to #3) GPU Fan Module - 18 - System Appearance...
  • Page 19: Front Panel Buttons And Leds

    Front Panel Buttons and LEDs No. Name Color Status Description Reset Button Press this button to reset the system. Indicates locating the HDD. Green Blink Indicates accessing the HDD. HDD Status Amber Indicates HDD error. Green / Blink Indicates HDD rebuilding. Amber Indicates no HDD access or no HDD error.
  • Page 20: Front System Lan Leds

    Front System LAN LEDs Name Color Status Description Yellow 1 Gbps data rate GbE Speed Green 100 Mbps data rate 10 Mbps data rate Link between system and network or no access Green GbE Link / Blink Data transmission or reception is occurring. Activity LED No data transmission or reception is occurring.
  • Page 21: Power Supply Unit (Psu) Led

    Power Supply Unit (PSU) LED PSU LED Color Status Description No AC power to all power supplies Green +12V output ON and OK Blinking Green AC present / Only +12VSB on (PS off) or PSU in Smart Standby Mode 0.5Hz Blinking Green Power supply firmware update...
  • Page 22: Hard Disk Drive Leds

    Hard Disk Drive LEDs LED#1 LED#2 (Reserved) HDD Present RAID SKU Rebuilding LED1 Locate HDD Fault Access (No Access) Disk LED Green ON(*1) BLINK (*2) (LED on Back Panel) Amber No RAID configuration Green ON(*1) (via HBA) Removed HDD Slot (LED on Back Panel) Amber Green...
  • Page 23: Chapter 3 System Hardware Installation

    Chapter 3 System Hardware Installation Pre-installation Instructions System components and electronic circuit boards can be damaged by electrostatic discharge. Working on systems that are still connected to a power supply can be extremely dangerous. Follow the simple guidelines below to avoid damage to your system or injury to yourself. •...
  • Page 24: Removing And Installing The Top Rear Cover

    Removing and Installing the Top Rear Cover Before you remove the top rear cover: • Make sure the system is not turned on or connected to AC power. Follow these instructions to remove the top rear cover: Remove the single screw securing the cover. Loosen the two thumbnail screws securing the top rear cover in place.
  • Page 25: Removing And Installing The Air Duct

    Removing and Installing the Air Duct Before you remove the top rear cover: • Make sure the system is not turned on or connected to AC power. Follow these instructions to remove and install the air duct: Lift up to remove the air duct. To install the air duct, align the rear edge of air duct with the GPU module brackets ensuring that the arrows on the air duct face the rear of the system as shown in the image below, and then push down the air duct into chassis until it firmly seats.
  • Page 26: Removing And Installing The Gpu Fan Module

    Removing and Installing the GPU Fan Module Before you remove the GPU fan module: • Make sure the system is not turned on or connected to AC power. • Disconnect all necessary cable connections. Failure to observe these warnings could result in personal injury or damage to the equipment.
  • Page 27: Installing The Gpu Card (Optional)

    Installing the GPU Card (Optional) Before you install the GPU card: • Voltages can be present within the server whenever an AC power source is connected. This voltage is present even when the main power switch is in the off position. Ensure that the system is powered down and all power sources have been disconnected from the server prior to installing a GPU card.
  • Page 28 System Hardware Installation - 28 -...
  • Page 29: Installing The Pcie Card

    Installing the PCIe Card Read the following guidelines before you begin to install the PCIe Card: • Voltages can be present within the server whenever an AC power source is connected. This voltage is present even when the main power switch is in the off position. Ensure that the system is powered down and all power sources have been disconnected from the server prior to installing a PCIe card.
  • Page 30 System Hardware Installation - 30 -...
  • Page 31: Removing And Installing The Heat Sink

    Removing and Installing the Heat Sink Read the following guidelines before you begin to install the heat Sink: • Always turn off the computer and unplug the power cord from the power outlet before installing the heat sink to prevent hardware damage. •...
  • Page 32: Removing And Installing The Cpu

    Removing and Installing the CPU Read the following guidelines before you begin to install the CPU: • Make sure that the motherboard supports the CPU. • Always turn off the system and unplug the power cord from the power outlet before installing the CPU to prevent hardware damage.
  • Page 33 • • When installing the heat sink over the CPU, use T20-Lobe driver to tighten the 4 captive nuts in sequential order (1g2g3g4). • • The screw tightening torque: 16.1 ± 1.2 kgf-cm (14.0± 1.0 lbf-in) - 33 - System Hardware Installation...
  • Page 34: Removing And Installing The Memory

    Removing and Installing the Memory Read the following guidelines before you begin to install the memory: • Make sure that the motherboard supports the memory. It is recommended that memory of the same capacity, brand, speed, and chips be used. •...
  • Page 35: Installing A Memory

    3-8-2 Installing a Memory • Before installing a memory module, make sure to turn off the system and unplug the power cord from the power outlet to prevent damage to the memory module. • Be sure to install DDR4 DIMMs on this motherboard. Follow these instructions to install the Memory: Insert the DIMM memory module vertically into the DIMM slot, and push it down.
  • Page 36: Memory Population Table

    3-8-4 Memory Population Table • • When only one DIMM is used, it must be populated in memory slot DIMM1. EPYC Memory Speed based on DIMM Population (One DIMM per Channel) DIMM Population DIMM Max EPYC 7003 Type DDR Frequency (MHz) DIMM 0 1R (1 Rank) 3200...
  • Page 37: Removing And Installing The 3.5" Hard Disk Drive

    Reinsert the HDD tray into the slot and close the locking lever. CAUTION! We strongly recommend using enterprise level hard disk drives in the Gigabyte server system. For more information of recommended HDDs, please visit the Gigabyte website: https://www.gigabyte.com and search for the specific product QVL from Support & Downloads.
  • Page 38 Follow these instructions to install a 2.5" hard disk drive into 3.5" HDD tray: Press the release button. Extend the locking lever. Pull the locking lever in the direction indicated to remove the HDD tray. Align the hard disk drive with the positioning stub on the HDD tray. Secure the hard disk drive with five screws.
  • Page 39: Replacing The System Fan Module

    3-10 Replacing the System FAN Module CAUTION! Before you remove or install the system fans follow these steps: • Make sure the system is not turned on or connected to the AC power. • Disconnect all necessary cable connections. Failure to observe these warnings could result in personal injury or damage to the equipment.
  • Page 40: Removing And Installing The Top

    3-11 Removing and Installing the Top Front Cover Skip this section if you are not going to replace the PCIe RAID card. Follow these instructions to remove the top front cover: Remove the three screws securing the cover. Slide the cover towards the rear and remove the cover in the direction indicated. Reverse the previous steps to install the top front cover.
  • Page 41: Removing And Installing The Pcie Raid Card

    3-12 Removing and Installing the PCIe RAID Card • Voltages can be present within the server whenever an AC power source is connected. This voltage is present even when the main power switch is in the off position. Ensure that the system is powered off and all power sources have been disconnected from the server prior to installing a PCIe card.
  • Page 42 System Hardware Installation - 42 -...
  • Page 43: Removing And Installing The Power Supply

    3-13 Removing and Installing the Power Supply CAUTION! • In order to reduce the risk of injury from electric shock, disconnect AC power from the power supply before removing the power supply from the system. • Please see Section 2-2 "Rear View" for installation sequence. Follow these instructions to replace the power supply: Flip up and then grasp the power supply handle.
  • Page 44: Cable Connections

    3-14 Cable Connections Motherboard to PCIe Board and Middle Board 14 13 System Hardware Installation - 44 -...
  • Page 45 HDD Backplane Boards to Daughter Boards 3.5” HDD Backplane Board Daughter Board 2 Daughter Board 1 - 45 - System Hardware Installation...
  • Page 46 This page left intentionally blank System Hardware Installation - 46 -...
  • Page 47: Chapter 4 Motherboard Components

    Chapter 4 Motherboard Components Motherboard Components CPU1 CPU0 Item Description Item Description SlimLine Connectors (PCIe Signal) SlimLine Connector (Front Panel Signal) USB 3.0 Header CPU Power Connector CPU 0 Power Connector CPU 1 Power Connector System Power Connector 2 x 9 Pin System FAN Power Connector 2 x 4 Pin Front Panel Power Connector Front Panel VGA Connector 2 x 7 Pin HDD Back Plane Board Power...
  • Page 48: Jumper Settings

    Jumper Settings CPU1 CPU0 HSMB_SEL BIOS Defined PMBUS_SEL BIOS Defined BIOS_PWD Normal (Default) Clear Supervisor Password BIOS_RCVR BIOS Recovery Mode Normal (Default) Clear CMOS Jumper CLR_CMOS Enable Default Motherboard Components - 48 -...
  • Page 49: Chapter 5 Bios Setup

    Chapter 5 BIOS Setup BIOS (Basic Input and Output System) records hardware parameters of the system in the EFI on the motherboard. Its major functions include conducting the Power-On Self-Test (POST) during system startup, saving system parameters and loading operating system, etc. BIOS includes a BIOS Setup program that allows the user to modify basic system configuration settings or to activate certain system features.
  • Page 50  Main This setup page includes all the items in standard compatible BIOS.  Advanced This setup page includes all the items of AMI BIOS special enhanced features. (ex: Auto detect fan and temperature status, automatically configure hard disk parameters.) ...
  • Page 51: The Main Menu

    The Main Menu Once you enter the BIOS Setup program, the Main Menu (as shown below) appears on the screen. Use arrow keys to move among the items and press <Enter> to accept or enter other sub-menu. Main Menu Help The on-screen description of a highlighted setup option is displayed on the bottom line of the Main Menu.
  • Page 52 Parameter Description BIOS Information Project Name Displays the project name information. Project Version Displays version number of the BIOS setup utility. Build Date and Time Displays the date and time when the BIOS setup utility was created. BMC Information BMC Firmware Version Displays version number of the BIOS setup utility.
  • Page 53 Parameter Description Total Memory Displays the total memory size of the installed memory. (Note1) Memory Speed Displays the frequency information of the installed memory. (Note1) VR Information Version Displays VR version information. AGESA PI Version PI Version Displays AGESA PI version information. Onboard LAN Information LAN1 MAC Address Displays LAN MAC address information.
  • Page 54: Advanced Menu

    Advanced Menu The Advanced menu display submenu options for configuring the function of various hardware components. Select a submenu item, then press [Enter] to access the related submenu screen. BIOS Setup - 54 -...
  • Page 55: Trusted Computing

    5-2-1 Trusted Computing Parameter Description Configuration Select Enable to activate TPM support feature. Security Device Support Options available: Enable/Disable. Default setting is Enable. SPI TPM Support Options available: Enabled/Disabled. Default setting is Enabled - 55 - BIOS Setup...
  • Page 56: Psp Firmware Versions

    5-2-2 PSP Firmware Versions The PSP Firmware Versions page displays the basic PSP firmware version information. Items on this window are non-configurable. BIOS Setup - 56 -...
  • Page 57: Legacy Video Select

    5-2-3 Legacy Video Select Parameter Description Select between onboard or external VGA support. OnBrd/Ext VGA Select Options available: Auto/Onboard/External. Default setting is Onboard. - 57 - BIOS Setup...
  • Page 58: Ast2500 Super Io Configuration

    5-2-4 AST2500 Super IO Configuration Parameter Description AST2500 Super IO Configuration Super IO Chip Displays the super IO chip information. BIOS Setup - 58 -...
  • Page 59 Parameter Description Press [Enter] to configure advanced items. Serial Port (Note1) Š – Enable/Disable the Serial Port (COM). When set to Enabled allows you to configure the Serial port 1/2 settings. When set to Disabled, displays no configuration for the serial port. –...
  • Page 60: S5 Rtc Wake Settings

    5-2-5 S5 RTC Wake Settings Parameter Description Enable or disable system wake on alarm event. Select Fixed Time, system will wake on the time (HH:MM:SS) specified. Select Dynamic Time and the Wake system from S5 system will wake at the current time plus an increase in minute(s). Options available: Disabled/Fixed Time.
  • Page 61: Serial Port Console Redirection

    5-2-6 Serial Port Console Redirection Parameter Description Select whether to enable console redirection for specified device. Console COM1/SOLConsole redirection enables the users to manage the system from a remote location. Redirection (Note) Options available: Enabled/Disabled. Default setting is Disabled. Selects a COM port for Legacy serial redirection. The options are Legacy Console Redirection dependent on the available COM ports.
  • Page 62 Parameter Description Bits per second Š – Selects the transfer rate for console redirection. – Options available: 9600/19200/38400/57600/115200. Default setting is 115200. Data Bits Š – Selects the number of data bits used for console redirection. – Options available: 7/8. Default setting is 8. Parity Š...
  • Page 63 Parameter Description Redirection COM Port Š – Selects a COM port to display redirection of Legacy OS and Legacy OPROM Messages. – Options available: COM1/SOL / COM2. Default setting is COM1/ SOL. Resolution Š Legacy Console Redirection – On Legacy OS, the number of rows and columns supported in Settings redirection.
  • Page 64: Cpu Configuration

    5-2-7 CPU Configuration Parameter Description CPU Configuration Enable/disable the CPU Virtualization. SVM Mode Options available: Enabled/Disabled. Default setting is Enabled. Controls the Secure Memory Encryption Enable (SMEE) function. SMEE Options available: Enabled/Disabled. Default setting is Enabled. CPU 0/1 Information Press [Enter] to view more information related to CPU 0. BIOS Setup - 64 -...
  • Page 65: Pci Subsystem Settings

    5-2-8 PCI Subsystem Settings - 65 - BIOS Setup...
  • Page 66 Parameter Description PCI Bus Driver Version Displays the PCI Bus Driver version information. Change the PCIe lanes. Options available: U2_P0_P#/U2_P1_P# Lanes Auto / x16 / x8 x8 / x8 x4 x4 / x4 x4 x8 / x4 x4 x4 x4 (Note1) (OCP2 Lanes only features Auto / x8 / x4 x4.) Disabled.
  • Page 67: Usb Configuration

    5-2-9 USB Configuration Parameter Description USB Configuration USB Module Version Displays the USB version. USB Controllers Displays the supported USB controllers. USB Devices Displays the USB devices connected to the system. Enable/disable the Legacy USB support fuction. AUTO option disables legacy support if no USB devices are connected.
  • Page 68 Parameter Description USB mass storage device Start Unit command time-out. Device reset time-out Options available: 10 sec/20 sec/30 sec/40 sec. Default setting is 20 sec. Maximum time the device will take before it properly reports itself to the Host Controller. "Auto" uses default value: for a Root port it is 100 ms, for Device power-up delay a Hub port the delay is taken from Hub descriptor.
  • Page 69: Nvme Configuration

    5-2-10 NVMe Configuration Parameter Description NVMe controller and Drive Displays the NVMe devices connected to the system. Information - 69 - BIOS Setup...
  • Page 70: Sata Configuration

    5-2-11 SATA Configuration BIOS Setup - 70 -...
  • Page 71: Network Stack Configuration

    5-2-12 Network Stack Configuration Parameter Description Enable/Disable the UEFI network stack. Network Stack Options available: Enabled/Disabled. Default setting is Enabled. Enable/Disable the Ipv4 PXE feature. Ipv4 PXE Support (Note) Options available: Enabled/Disabled. Default setting is Enabled. Enable/Disable the Ipv4 HTTP feature. Ipv4 HTTP Support (Note) Options available: Enabled/Disabled.
  • Page 72: Uefi Post Logo Configuration

    5-2-13 UEFI POST LOGO Configuration Parameter Description UEFI Configuration Select output device. Options available: First loaded Device,Onboard Device,External Device, Output Device Type Specific Device. Default setting is Onboard Deviceevice. BIOS Setup - 72 -...
  • Page 73: Amd Mem Configuration Status

    5-2-14 AMD Mem Configuration Status Parameter Description Press [Enter] for configuration of advanced items. Channel A/BC/D/E/F/G/H Š – DIMM0 Presence – DIMM1 Presence CPU 0/1 – Chipset/Bank Interleave Dram EC Š Dram Parity Š Dimm Sensor Fine Grain Mode Š - 73 - BIOS Setup...
  • Page 74: Tls Auth Configuration

    5-2-15 Tls Auth Configuration Parameter Description Press [Enter] for configuration of advanced items. Enroll Cert Š – Press [Enter] to enroll a certificate • Enroll Cert Using File • Cert GUID Server CA Configuration Input digit character in 1111111-2222-3333-4444- 1234567890ab format. –...
  • Page 75: Intel(R)Ethernet Controller X550

    5-2-16 Intel(R)Ethernet Controller X550 - 75 - BIOS Setup...
  • Page 76 Parameter Description Press [Enter] to configure advanced items. Link Speed Š – Allows for automatic link speed adjustment. – Options available: Auto Negotiated/10 Mbps Half/10 Mbps Full/100 Mbps Half/100 Mbps Full. Default setting is Auto Negotiated. NIC Configuration Wake On LAN Š...
  • Page 77: Vlan Configuration

    5-2-17 VLAN Configuration Parameter Description Press [Enter] to configure advanced items. Create new VLAN Š VLAN ID Š – Sets VLAN ID for a new VLAN or an existing VLAN. – Press the <+> / <-> keys to increase or decrease the desired values. The valid range is from 0 to 4094.
  • Page 78: Mac Ipv4 Network Configuration

    5-2-18 MAC IPv4 Network Configuration Parameter Description Indicates whether network address is configured successfully or not. Configured Options available: Disabled/Enabled. Default setting is Disabled. Enable DHCP Options available: Enabled/Disabled. Default setting is Enabled. (Note) Local IP Address Press [Enter] to configure local IP address. (Note) Local NetMask Press [Enter] to configure local NetMask.
  • Page 79: Mac Ipv6 Network Configuration

    5-2-19 MAC IPv6 Network Configuration Parameter Description Press [Enter] for configuration of advanced items. Interface Name Š Interface Type Š MAC address Š Host address Š Route Table Š Gateway addresses Š DNS addresses Š Interface ID Š Enter Configuration Menu –...
  • Page 80: Amd Cbs Menu

    AMD CBS Menu AMD CBS menu displays submenu options for configuring the CPU-related information that the BIOS automatically sets. Select a submenu item, then press [Enter] to access the related submenu screen. BIOS Setup - 80 -...
  • Page 81: Cpu Common Options

    5-3-1 CPU Common Options Parameter Description Valhalla Common Options Press [Enter] for more options. Custom Core Pstates Š – Allows you to accept or decline custom core pstates. When accepted you can disable or customize ceratin pstates. Performance CCD/Core/Thread Enablement Š...
  • Page 82 Parameter Description From a workaroud for GCC/C000005 issue for XV Core on CZ A0, setting MSRC001_1029 Decode Configuration (DE_CFG) bit 14 RedirectForReturnDis [DecfgNoRdrctForReturns] to 1. Options available: Auto/1/0. Default option is Auto. Enable/Disable PFEH, cloak individual banks, and mask deferred error Platform First Error Warning interrupts from each bank.
  • Page 83 Parameter Description By default (Auto) the bronze workaround is applied. Bronze workaround: DbReq and PDM function as expected, breakpoint redirect capability compromised. Xtrig7 Workaround Silver workaround: DbReq, PDM, and breakpoint redirect function as expected, SCAN capability compromised. Options available: Auto/No Workaround/Bronze Workaround/Silver Workaround.
  • Page 84: Df Common Options

    5-3-2 DF Common Options Parameter Description Press [Enter] for configuration of advanced items. DRAM scrub time Š – Provides a value that is the number of hours to scrub memory. – Options available: Disabled/1 hour/4 hours/8 hours/16 hours/24 hours/48 hours/Auto. Default option is Auto. Poison scrubber control Š...
  • Page 85 Parameter Description Press [Enter] for more options. NUMA notes per socket Š – Specifies the number of desired NUMA (Non-uniform Memory Access) notes per socket. Zero will attempt to interleave the two sockets together. – Options available: NPS0/NPS1/NPS2/NPS4/Auto. Default option is Auto.
  • Page 86 Parameter Description Press [Enter] for more options. GMI encryption control Š – Control GMI link encryption. – Options available: Disable/Enable/Auto. Default option is Auto. xGMI encryption control Š – Control xGMI link encryption.Options available: Disable/Enable/ Auto. Default option is Auto. CAKE CRC perf bounds control Š...
  • Page 87: Umc Common Options

    5-3-3 UMC Common Options Parameter Description Press [Enter] for more options. Enforce POR Š – Press [Enter] to configure the enforcement of Plan Of Record (POR) which enables enforcement of POR restrictions for DDR4 frequency and voltage programming. DRAM Controller Configuration Š...
  • Page 88 Parameter Description Press [Enter] for more options Chipselect Interleaving Š – Interleave memory blocks across the DRAM chip slects for node 0 – Options available: Disabled/Auto. Default option is Auto. BankGroupSwap Š – Configures the BankGroupSwap. BankGroupSwap (BGS) is a memory mapping option in AGESA that alters how applications get assigned to physical locations within the memory modules.
  • Page 89: Nbio Common Options

    5-3-4 NBIO Common Options Parameter Description NBIO Common Options Enable/Disable IOMMU. IOMMU Options available: Enabled/Disabled. Default setting is Disabled. AER must be enabled for ACS enable to work. ACS Enable Options available: Enable/Disabled/Auto. Default option is Auto. Enables Alternative Routing ID Interpretation. PCIe ARI Support Options available: Disable/Enable/Auto.
  • Page 90 Parameter Description Press [Enter] for more options. Determinism Control Š – Auto = Use the fused determinism, Manual = User can set customized determinism. – Options available: Manual/Auto. Default option is Manual. cTDP Control Š – Auto = Use the fused TDP, Manual = User can set customized TDP.
  • Page 91 Parameter Description Press [Enter] for more options. NBIO RAS Global Control Š – Options available: Manual/Auto. Default option is Auto. NBIO RAS Control Š – 0 = Disabled, 1 = MCA, 2 = Legacy. – Options available: Disabled/MCA/Legacy. Default option is MCA. Egress Poison Severity High Š...
  • Page 92 Parameter Description System Hub Watchdog Timer Š – Enter a value. This value specifies the timer interval of the SYSHUB watchdog timer in miliseconds. SLINK Read Response OK Š – This value specifies whether SLINK read response errors are converted to an Okay response. When this value is set to TRUE, read response errors are converted to Okay responses with data of all FFs.
  • Page 93 Parameter Description Sync Flood on PCIe Fatal Error Š – When 'Sync Flood on PCIe Fatal Error' is True, PcdAmdPcieSyncFloodOnFatal should be set to True. When 'Sync NBIO RAS Common Options Flood on PCIe Fatal Error' is False, PcdAmdPcieSyncFloodOnFatal (continued) should be set to False.
  • Page 94: Fch Common Options

    5-3-5 FCH Common Options Parameter Description FCH Common Options SATA Enable Š – Enable or disable OnChip SATA controller. – Options available: Disabled/Enabled/Auto. Default setting is Auto. SATA RAS Support Š – Enable or disable SATA RAS support. – Options available: Disabled/Enabled/Auto. Default setting is Auto. SATA Configuration Options Sata Disabled AHCI Prefetch Function Š...
  • Page 95 Parameter Description Press [Enter] for more options. XHCI Controller0 Enable Š – Enable or disable USB3 controller. – Options available: Enabled/Disabled/Auto. Default setting is Auto. XHCI Controller1 Enable Š USB Configuration Options – Enable or disable USB3 controller. – Options available: Enabled/Disabled/Auto. Default setting is Auto. USB ecc SMI Enable Š...
  • Page 96 Parameter Description Press [Enter] for more options. eMMC/SD Configure Š – Options available: Disabled/SD Normal Speed/SD High Speed/SD UHSI-SDR50/SD UHSI-DDR50/SDUHSI-SDR104/eMMC Emmc Backward Compatibility/eMMC High Speed SDR/eMMC High Speed DDR/eMMC HS200/eMMCHS400/eMMC HS300/Auto. Default setting is Auto. eMMC Options Driver Type Š –...
  • Page 97: Ntb Common Options

    5-1-1 NTB Common Options Parameter Description NTB Common Options Enable or disable OnChip SATA controller. NTB Enable Options available: Auto/Enable. Default setting is Auto. - 97 - BIOS Setup...
  • Page 98: Soc Miscellaneous Control

    5-1-1 SOC Miscellaneous Control Parameter Description Soc Miscellaneous Control Enable = Enable ConsoleOut Function for ABL Disable = Disable ConsoleOut Function for ABL ABL Console Out Control Auto = Keep default behavior Options available: Disable/Enable/Auto. Default setting is Auto. BIOS Setup - 98 -...
  • Page 99: Amd Pbs Option Menu

    AMD PBS Option Menu AMD PBS Option menu displays submenu options for configuring the function of AMD PBS. Select a submenu item, then press [Enter] to access the related submenu screen. Parameter Description AMD PBS Press [Enter] for advanced configurations. Enable or disable SPI Locking for protect ROM part.
  • Page 100: Ras

    5-1-1 RAS Parameter Description Enable or disable Periodic SMI for polling [MCA Threshold] error. RAS Periodic SMI Control Options Available: Disabled/Enabled. Default option is Enabled. Enter a value. Limits the number of [MCA Threshold and Deferred Error SMI source] SMI Threshold per a unit of time (Defined by [SMI Scale]).
  • Page 101 Parameter Description PCIe UnCorr GHES Notify Notification type for PCIe uncorrected errors. Type Options Available: Polled/NMI. Default option is NMI. PCIe Root Port Corr Err Mask Enter a value. Intialize the PCIe AER Corrected Error Mask register of Root Port. PCIe Root Port UnCorr Err Enter a value.
  • Page 102: Chipset Setup Menu

    Chipset Setup Menu Chipset Setup menu displays submenu options for configuring the function of the SoC. Select a submenu item, then press [Enter] to access the related submenu screen. Parameter Description PCIe Link training in 1 or 2 steps. PCIe Link Training Type Options available: 1 Step/2Step.
  • Page 103: Server Management Menu

    Server Management Menu Parameter Description FRB-2 Timer FRB-2 timer (POST timer). Configure the FRB2 Timer timeout. Options available: 3 minutes/4 minutes/5 minutes/6 minutes. Default setting is 6 FRB-2 Timer minutes. timeout (NOTE) This item is configurable when FRB-2 Timer is set to Enabled. Configure the FRB2 Timer policy.
  • Page 104 Parameter Description View FRU Press [Enter] to view the advanced items. Information BMC network Press [Enter] to configure advanced items. configuration IPv6 BMC Network Press [Enter] to configure advanced items. Configuration BIOS Setup - 104 -...
  • Page 105: System Event Log

    5-6-1 System Event Log Parameter Description Enabling / Disabling Options Change this item to enable or disable all features of System Event SEL Components Logging during boot. Options available: Enabled/Disabled. Default setting is Enabled. Erasing Settings Choose options for erasing SEL. Erasing SEL Options available: No/Yes, On next reset/Yes, On every reset.
  • Page 106: View Fru Information

    5-6-2 View FRU Information The FRU page is a simple display page for basic system ID information, as well as System product information. Items on this window are non-configurable. (Note) The model name will vary depends on the product you purchased. BIOS Setup - 106 -...
  • Page 107: Bmc Network Configuration

    5-6-3 BMC Network Configuration Parameter Description BMC network configuration Lan Channel 1 Select to configure LAN channel parameters statically or dynamically (DHCP). Do nothing option will not modify any BMC network parameters Configuration Address source during BIOS phase. Options available: Unspecified/Static/DynamicBmcDhcp. Default setting is DynamicBmcDhcp.
  • Page 108: Ipv6 Bmc Network Configuration

    5-6-4 IPv6 BMC Network Configuration Parameter Description IPv6 BMC Network Configuration IPv6 BMC Lan Channel 1 Enable/Disable IPv6 BMC LAN channel function. When this item is IPv6 BMC Lan Option disabled, the system will not modify any BMC network during BIOS phase. Options available: Unspecified/Disable/Enable.
  • Page 109: Security Menu

    Security Menu The Security menu allows you to safeguard and protect the system from unauthorized use by setting up access passwords. There are two types of passwords that you can set: • Administrator Password Entering this password will allow the user to access and change all settings in the Setup Utility. •...
  • Page 110: Secure Boot

    5-7-1 Secure Boot Parameter Description System Mode Displays the system is in User mode or Setup mode. Enables/Disables Secure Boot. The mode change requires a platform Secure Boot reset. Options available: Disabled/Enabled. Default setting is Disabled. Secure Boot requires all the applications that are running during the booting process to be pre-signed with valid digital certificates.
  • Page 111 Parameter Description Factory Key Provision Š – Installs factory default Secure Boot keys after the platform resets and the system is in Setup Mode. – Options available: Disabled/Enabled. Default setting is Disabled. Restore Factory Keys Š – Installs factory default Secure Boot key databases. It will force the system in User Mode.
  • Page 112: Boot Menu

    Boot Menu The Boot menu allows you to set the drive priority during system boot-up. BIOS setup will display an error message if the legacy drive(s) specified is not bootable. Parameter Description Boot Configuration Number of seconds to wait for setup activation key. 65535 (0xFFFF) Setup Prompt Timeout means indefinite waiting.
  • Page 113 Parameter Description UEFI Network Drive BBS Press [Enter] to configure the boot priority. Priorities UEFI Application Boot Priorities Press [Enter] to configure the boot priority. - 113 - BIOS Setup...
  • Page 114: Uefi Network Drive Bbs Priorities

    5-8-1 UEFI NETWORK Drive BBS Priorities The UEFI network drive BBS priorities submenu allows you to specify the boot device priority from the available UEFI network drives during system boot-up. BIOS setup will display an error message if the legacy drive(s) specified is not bootable.
  • Page 115: Uefi Application Boot Priorities

    5-8-2 UEFI Application Boot Priorities The UEFI application boot priorities submenu allows you to specify the boot device priority from the available UEFI applications during system boot-up. BIOS setup will display an error message if the legacy drive(s) specified is not bootable. - 115 - BIOS Setup...
  • Page 116: Save & Exit Menu

    Save & Exit Menu The Exit menu displays the various options to quit from the BIOS setup. Highlight any of the exit options then press [Enter]. Parameter Description Save Options Saves changes made and closes the BIOS setup. Save Changes and Exit Options available: Yes/No.
  • Page 117: Bios Post Beep Code (Ami Standard)

    5-10 BIOS POST Beep code (AMI standard) 5-10-1 PEI Beep Codes # of Beeps Description Memory not Installed. Memory was installed twice (InstallPeiMemory routine in PEI Core called twice) Recovery started DXEIPL was not found DXE Core Firmware Volume was not found Recovery failed S3 Resume failed Reset PPI is not available...

Table of Contents