B. Cleaning and Sanitizing Instructions
The icemaker must be cleaned and sanitized at least once a year. More frequent
cleaning and sanitizing may be required in some water conditions.
• To prevent injury to individuals and damage to the icemaker, do not use ammonia
type cleaners.
• Carefully follow any instructions provided with the bottles of cleaning and
sanitizing solution.
• Always wear liquid-proof gloves and goggles to prevent the cleaning and sanitizing
solutions from coming into contact with skin or eyes.
To prevent damage to the water pump seal, do not operate the icemaker with the
control switch in the "SERVICE" position when the water tank is empty.

1. Cleaning Procedure

1) Dilute 22 fl. oz. (650 ml) of Hoshizaki "Scale Away" with 4 gal. (15 l) of warm water.
2) Remove all ice from the evaporator and the dispenser unit/storage bin.
Note: To remove cubes on the evaporator, turn off the power supply and turn it back on
after 3 minutes. The harvest cycle starts and the cubes will be removed from the
evaporator.
3) Turn off the power supply.
4) Remove the front panel, then place the control switch in the "SERVICE" position. Place
the service switch in the "DRAIN" position.
5) Replace the front panel in its correct position, then turn on the power supply for
2 minutes.
6) Turn off the power supply.
7) Remove the front panel.
Fig. 20
WARNING
NOTICE
Float Switch
Splash Curtain
31
Insulation Panel
Front Panel