Download Print this page

Wiring Diagram - Makita HS7100K Technical Information

190mm (7-1/2")

Advertisement

W
iring diagram
Fig. D-2
HS6100 & HS7100
(without Electric brake and LED light)
Be careful not to put Lead wire (blue or white)
of Power supply cord on Noise suppressor
after connecting it to Terminal block.
Be careful not to put
Lead wires on the boss
and ribs A, B, C, D.
Strain relief
rib A
Noise suppressor
(if used)
If Noise suppressor is used,
route Noise suppressor's lead
wires between rib A and rib B.
Be careful not to put them on
Noise suppressor, ribs A and B.
Switch
rib C
rib D
rib B
boss
Terminal block
Set Terminal block in Handle section
with each terminal positioned as follows:
*On Strain relief side, the terminal with which
the Lead wire of Power supply cord is connected
must be positioned.
*On Field side, the terminal with which the Field
lead wire is connected must be positioned.
Route Field lead wires
into Handle section
through this groove.
P 14/16
Field lead wires must be
tight in Motor housing.
Field
Fix Field lead wires
in these Lead wire
holders.
Field lead wires must be
tight in Motor housing.