Mitsubishi Electric PLFY-P32VBM-ER2.UK Technical & Service Manual page 14

Hide thumbs Also See for PLFY-P32VBM-ER2.UK:
Table of Contents

Advertisement

Model
Power source
Cooling capacity
(Nominal)
Power input
Current input
Heating capacity
(Nominal )
Power input
Current input
External finish
External dimension H × W × D
Net weight
Decoration panel
Model
External finish
Dimension
H × W × D
Net weight
Heat exchanger
FAN
Type × Quantity
External
static press.
Motor type
Motor output
Driving mechanism
Airflow rate
(Low-Mid2-
Mid1-High)
Noise level (Low-Mid2-Mid1-High)
(measured in anechoic room)
Insulation material
Air filter
Protection device
Refrigerant control device
Connectable outdoor unit
Liquid
Diameter of
refrigerant pipe
Gas
Field drain pipe size
Document
Standard
Accessory
attachment
Remark
Optional parts
Decoration panel **1
Air outlet shutter plate
High efficiency filter
element **2
Multi-function casement
Installation
Note :
1 Nominal cooling conditions
Indoor :
27 DB/19 WB (81°FDB/66°FWB)
Outdoor :
35 DB (95°FDB)
Pipe length :
7.5 m (24-9/16 ft)
Level difference :
0 m (0 ft)
* Nominal conditions 1, 3 are subject to JIS B8615-1.
* Due to continuing improvement, above specification may be subject to change without notice.
OCH413D
PLFY-P80VBM-E
kW
9.0
1
kcal / h
7,700
1
Btu / h
30,700
1
kcal / h
8,000
2
kW
0.07
A
0.51
kW
10.0
3
kcal / h
8,600
3
Btu / h
34,100
3
kW
0.06
A
0.43
mm
258 x 840 x 840
in.
10-3/16 x 33-1/8 x 33-1/8
kg (lb)
23(51)
PLP-6BA
mm
in.
kg (lb)
Turbo fan x 1
Pa
0
mmH
O
0
2
kW
0.050
16 - 18 - 20 - 22
m
/ min
3
267 - 300 - 333 - 367
L / s
565 - 636 - 706 - 777
cfm
30 - 32 - 35 - 37
dB <A>
mm (in.)
9.52 ( 3/8)
mm (in.)
15.88 ( 5/8)
mm (in.)
PLP-6BA
PAC-SH51SP-E
PAC-SH59KF-E
PAC-SH53TM-E
**1. PLFY-P-VBM-E should use together with PLP-6BA.
**2. PAC-SH53TM-E is necessary to use with filter PAC-SH59KF-E.
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to
the Installation Manual.
2 Nominal cooling conditions
27 DB/19.5 WB (81°FDB/67°FWB)
35 DB (95°FDB)
5 m (16-3/8 ft)
0 m (0 ft)
PLFY-P100VBM-E
1-phase 220-240V 50Hz, 1-phase 220V 60Hz
11.2
9,600
38,200
10,000
0.15
1.00
12.5
10,800
42,700
0.14
0.94
Galvanized steel sheet
298 x 840 x 840
11-3/4 x 33-1/8 x 33-1/8
27(60)
PLP-6BA
MUNSELL (6.4Y 8.9/0.4)
35 x 950 x 950
1-3/8 x 37-7/16 x 37-7/16
6(13)
Cross fin (Aluminum fin and copper tube)
Turbo fan x 1
0
0
DC motor
0.120
Direct-drive
21 - 24 - 27 - 29
350 - 400 - 450 - 483
742 - 848 - 953 - 1024
34 - 37 - 39- 41
PP honeycomb
Fuse
R410A CITY MULTI
Flare
9.52 ( 3/8)
Flare
Flare
15.88 ( 5/8)
Flare
O.D. 32 (VP-25)
Installation Manual, Instruction Book
PLP-6BA
PAC-SH51SP-E
PAC-SH59KF-E
PAC-SH53TM-E
3 Nominal heating conditions
20 DB (68°FDB)
7 DB/6CWB (45°FDB/43°FWB)
7.5 m (24-9/16 ft)
0 m (0 ft)
14
PLFY-P125VBM-E
14.0
12,000
47,800
12,500
0.16
1.07
16.0
13,800
54,600
0.15
1.00
27(60)
PLP-6BA
Turbo fan x 1
0
0
0.120
22 - 25 - 28 - 30
367 - 417 - 467 - 500
777 - 883 - 989 - 1059
35 - 38 - 41 - 43
PS
LEV
9.52 ( 3/8)
Flare
15.88 ( 5/8)
Flare
PLP-6BA
PAC-SH51SP-E
PAC-SH59KF-E
PAC-SH53TM-E
*Above specification data is
subject to rounding variation.
Unit converter
×
kcal/h = kW
860
×
Btu/h = kW
3,412
×
cfm
= m
3
/min
35.31
lb
= kg / 0.4536

Advertisement

Table of Contents
loading

Table of Contents