Specifications - Mitsubishi Electric PLFY-P32VBM-ER2.UK Technical & Service Manual

Hide thumbs Also See for PLFY-P32VBM-ER2.UK:
Table of Contents

Advertisement

4

SPECIFICATIONS

4-1. SPECIFICATIONS
Model
Power source
Cooling capacity
(Nominal)
Power input
Current input
Heating capacity
(Nominal )
Power input
Current input
External finish
External dimension H × W × D
Net weight
Decoration panel
Model
External finish
Dimension
H × W × D
Net weight
Heat exchanger
FAN
Type × Quantity
External
static press.
Motor type
Motor output
Driving mechanism
Airflow rate
(Low-Mid2-
Mid1-High)
Noise level (Low-Mid2-Mid1-High)
(measured in anechoic room)
Insulation material
Air filter
Protection device
Refrigerant control device
Connectable outdoor unit
Liquid
Diameter of
refrigerant pipe
Gas
Field drain pipe size
Document
Standard
Accessory
attachment
Remark
Optional parts
Decoration panel **1
Air outlet shutter plate
High efficiency filter
element **2
Multi-function casement
Installation
Note :
1 Nominal cooling conditions
Indoor :
27 DB/19 WB (81°FDB/66°FWB)
Outdoor :
35 DB (95°FDB)
Pipe length :
7.5 m (24-9/16 ft)
Level difference :
0 m (0 ft)
* Nominal conditions 1, 3 are subject to JIS B8615-1.
* Due to continuing improvement, above specification may be subject to change without notice.
OCH413D
PLFY-P32VBM-E
kW
3.6
1
kcal / h
3,100
1
Btu / h
12,300
1
kcal / h
3,150
2
kW
0.03
A
0.22
kW
4.0
3
kcal / h
3
3,400
Btu / h
13,600
3
kW
0.02
A
0.14
mm
in.
kg (lb)
22 (49)
PLP-6BA
mm
in.
kg (lb)
Turbo fan × 1
Pa
0
mmH
O
0
2
kW
0.050
m
3
/ min
11 - 12 - 13 - 14
L / s
183 - 200 - 217 - 233
cfm
388 - 424 - 459 - 494
27 - 28 - 29 - 31
dB <A>
6.35 ( 1/4)
mm (in.)
12.7 ( 1/2)
mm (in.)
mm (in.)
PLP-6BA
PAC-SH51SP-E
PAC-SH59KF-E
PAC-SH53TM-E
**1. PLFY-P-VBM-E should use together with PLP-6BA.
**2. PAC-SH53TM-E is necessary to use with filter PAC-SH59KF-E.
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to
the Installation Manual.
2 Nominal cooling conditions
27 DB/19.5 WB (81°FDB/67°FWB)
35 DB (95°FDB)
5 m (16-3/8 ft)
0 m (0 ft)
PLFY-P40VBM-E
1-phase 220-240V 50Hz, 1-phase 220V 60Hz
4.5
3,900
15,400
4,000
0.04
0.29
5.0
4,300
17,100
0.03
0.22
Galvanized steel sheet
258 x 840 x 840
10-3/16 x 33-1/8 x 33-1/8
22 (49)
PLP-6BA
MUNSELL (6.4Y 8.9/0.4)
35 x 950 x 950
1-3/8 x 37-7/16 x 37-7/16
6 (13)
Cross fin (Aluminum fin and copper tube)
Turbo fan × 1
0
0
DC motor
0.050
Direct-drive
12 - 13 - 14 - 16
200 - 217 - 233 - 267
424 - 459 - 494 - 565
27 - 28 - 30 - 31
PP honeycomb
Fuse
LEV
R410A CITY MULTI
Flare
6.35 ( 1/4)
Flare
Flare
12.7 ( 1/2)
Flare
O.D. 32 (VP-25)
Installation Manual, Instruction Book
PLP-6BA
PAC-SH51SP-E
PAC-SH59KF-E
PAC-SH53TM-E
3 Nominal heating conditions
20 DB (68°FDB)
7 DB/6 WB (45°FDB/43°FWB)
7.5 m (24-9/16 ft)
0 m (0 ft)
13
13
PLFY-P50VBM-E
5.6
4,800
19,100
5,000
0.04
0.29
6.3
5,400
21,500
0.03
0.22
22 (49)
PLP-6BA
Turbo fan × 1
0
0
0.050
12 - 13 - 14 - 16
200 - 217 - 233 - 267
233 - 250 - 267 - 300
424 - 459 - 494 - 565
494 - 530 - 565 - 636
27 - 28 - 30 - 31
PS
6.35 ( 1/4)
Flare
12.7 ( 1/2)
Flare
15.88 ( 5/8)
PLP-6BA
PAC-SH51SP-E
PAC-SH59KF-E
PAC-SH53TM-E
*Above specification data is
subject to rounding variation.
PLFY-P63VBM-E
7.1
6,100
24,200
6,300
0.05
0.36
8.0
6,900
27,300
0.04
0.29
23 (51)
PLP-6BA
Turbo fan × 1
0
0
0.050
14 - 15 - 16 - 18
28 - 29 - 30 - 32
9.52 ( 3/8)
Flare
Flare
PLP-6BA
PAC-SH51SP-E
PAC-SH59KF-E
PAC-SH53TM-E
Unit converter
×
kcal/h = kW
860
×
Btu/h = kW
3,412
×
3
cfm
= m
/min
35.31
lb
= kg / 0.4536

Advertisement

Table of Contents
loading

Table of Contents