Notice

Air ow
Air ow is not blown out when starting the HEATING
operation.
Air ow is not blown out for 5 to 15 min. or blown out not
warm wind for a moment at HEATING operation.
Air ow is not blown out when starting the DRY operation.
Noise
You hear a slight gurgling sound.
You hear a slight cracking sound.
You hear a hissing or clicking sound.
Whistling noise is heard from the outdoor unit.
Sometimes a "Shooooo" sound might come for a short
time from the unit that is turned off.
Others
The unit does not restart immediately after you have
stopped it.
Some steam escapes during COOL operation.
There is a slight smell.
After a power cut, the unit does not restart even if power
has been restored.
Remote control signals are not received.
Moisture may form on the air outlet grills.
Fan will not stop immediately after unit operation was
stopped.
RUN light stays on even though operation was stopped.
RUN light blinks slowly
(1.5 sec ON, 0.5 sec OFF)
RUN light blinks slowly
(1.5 sec ON, 0.5 sec OFF)
(RUN light is on)
(RUN light is on)
Not
operating?
EN-31
Air ow has stopped to prevent blowing out of cold air until the
indoor heat exchanger has warmed up. (2 to 5 min.) (HOT
KEEP program)
When outdoor temperature is low and humidity is high, the
unit sometimes performs defrosting automatically. Please
wait. During defrosting, water or steam may escape from the
outdoor unit.
The indoor fan may stop to prevent re-evaporation of
dehumi ed moisture and to save energy.
This is caused by refrigerating liquid moving within the unit.
This is caused by heat expansion or contraction.
This is caused by the operation of the refrigerant control
valves or electric components.
The noise means that the revolution speed of the compressor
is increasing or decreasing.
This is the sound when operation of another indoor unit is
stopped.
Restart is blocked for 3 minutes after you have stopped the
operation to protect the unit.
Please wait for
three minutes.
The three-minute protection timer in the microcomputer
automatically starts it up again.
This may occur if the room's temperature and humidity are
very high. It disappears as soon as the temperature and
humidity decrease.
Air blown out during operation may smell. This is caused by
tobacco or cosmetics adhering to the unit.
If the auto restart function is not set, the unit will not restart
automatically. Use the remote control to start the operation
again.
Remote control signals may not be received if the unit display
section is exposed to direct sunlight or other bright light.
If so, cut out the sunlight or reduce the other light.
If the unit is operated for a long time in high humidity, moisture
may form on the air outlet grills and start dripping.
Indoor fan
: Fan will not stop after 2 hours if set to SELF
CLEAN operation.
Outdoor fan : Fan will not stop about a 1 minute period in
order to protect the unit.
The RUN light illuminates during SELF CLEAN operation.
Run light turns off when SELF CLEAN operation ends.