Chamberlain ESTATE SERIES SW 2000-X3 Installation Manual page 43

Estate series x3 controller board heavy duty high cycle swing gate operator
Table of Contents

Advertisement

ADJUSTMENTS
OBSTRUCTION
RIGHT (R69)
OBSTRUCTION
LEFT (R160)
NOTE: LiftMaster gate operators have two obstruction sense adjustments (left and
right) where other gate operators have only one. This allows greater
flexibility of installation. For instance, you can install a gate on an incline
and not worry about sacrificing downhill gate sensitivity.
INRUSH
(R203)
CONNECTORS
LIMIT SWITCH (J4)
PWR INPUT (J1)
MOTOR POWER (J3) Connector for the motor cable.
LOOP DETECTOR
(J15)
LOOP DETECTOR
(J12)
LOOP DETECTOR
(J13)
LOOP DETECTOR
(J14)
OBSTRUCTION
ALARM
37 of 42
Adjustable pot controls gate sensitivity to blockages by the
instantaneous rise in motor current. When the limit is exceeded, the
gate stops and reverses a programmed distance (a minimum of 2
inches).
Adjustable pot controls gate sensitivity to blockages by the
instantaneous rise in motor current. When the limit is exceeded, the
gate stops and reverses a programmed distance (a minimum of 2
inches).
Adjustable pot controls the delay in sensitivity to gate
obstructions. This delay in sensitivity prevents the initial motor
inrush current from causing a obstruction fault. The weight of the
gate determines this setting.
Connector for the left/right limit switch cable.
Connector for AC input power.
Connector for the optional LiftMaster Outside Interrupt Loop
detector
add-on board.
Connector for the optional LiftMaster Inside Interrupt Loop detector
add-on board.
Connector for optional LiftMaster Shadow Loop detector add-on
board.
Connector for optional LiftMaster Exit Loop detector add-on board.
Connector for factory-installed alarm.
Doc 01-20099
Rev F

Advertisement

Table of Contents
loading

This manual is also suitable for:

Liftmaster sw 2000-x3

Table of Contents