I. SETTING LIMIT CAMS
Adjust the limit cams by loosening the clamp and rotating the cams. The cams
rotate with the swing arm shaft, so small adjustments are magnified by the length
of the gate.
Use manual controls to move the gate during limit cam adjustment.
To avoid damage to the gate and gate operator due to the gate overrunning its
limits, perform the following steps carefully:
1. SETTING RIGHT GATE LIMIT CAMS
Top Limit Cam
Top Limit Switch
1. Make sure that switch S2 is set to the "Right" position.
2. Turn on gate operator power switch.
3. Using manual CLOSE and STOP, move the gate to its proper closed limit position.
4. Loosen the clamp on the bottom limit cam and turn the cam clockwise until it just
barely closes the limit switch.
5. Retighten the clamp. Do not overtighten.
6. Using manual OPEN and STOP, move the gate to its proper open limit position.
7. Loosen the clamp on the top limit cam and turn the cam counterclockwise until it
just barely closes the limit switch.
8. Retighten the clamp. Do not overtighten.
9. Open and close the gate to check the limit cam settings. If required, readjust the
limit cams until they are set properly.
RevMF
Open Gate
Bottom Limit Cam
Bottom Limit Switch

Figure 8. Setting Right Gate Limit Cam

Doc 01-20099
Closed Gate
01-20099F1
11 of 42