Connecting Cable Connection - Toshiba RAS-M16PKVPG-E Installation Manual

Multiple type
Hide thumbs Also See for RAS-M16PKVPG-E:
Table of Contents

Advertisement

Connecting cable
CAUTION
Power supply must input at Outdoor Unit Terminal Block.
Wiring Diagram
Indoor
1
2
Terminal
Block
Outdoor
1(L)
2
3
Terminal
Block
CAUTION
1. The power supply must be same as the rated of air conditioner.
2. Prepare the power source for exclusive use with air conditioner.
3. Circuit breaker must be used for the power supply line of this air conditioner.
4. Be sure to comply power supply and connecting cable for size and wiring method.
5. Every wire must be connected fi rmly.
6. Perform wiring works so as to allow a general wiring capacity.
7. Wrong wiring connection may cause some electrical part burn out.
8. Incorrect or incomplete wiring is carried out, it will cause an ignition or smoke.

Connecting Cable Connection

Connecting cable connect to
terminal block (1, 2, 3, ˙)
3
Chassis
L
N
L N GND
Power supply input
Stripping length of the connecting cable
50 mm
10 mm
3
10 mm
45 mm
11
Earth line
Connecting cable
EN