MD-R2H
• Disc motor fails to run
Does waveform appear on the pins 24 and 25 of IC1201 in the
TEST mode focus gain coarse adjustment step?
Does waveform appear on the pins 34 and 35 of IC1601, pins
1 and 2 of CNP1603?
Replace the completed disc motor.
• Tracking servo failure
Does waveform appear on the pins 8 and 9 of IC1601, and pins
1 and 3 of CNS1101 in the TEST mode focus gain adjustment
step?
Replace the optical pickup.
• Slide servo failure
Does the pickup move to external and internal periphery when
the
or
button is pressed in the TEST mode?
Is there any change on the pins 22 and 23 of IC1201 when the
or
button is pressed?
Is there any change on the pins 28 and 29 of IC1601, and the
pins 1 and 2 of CNP1602 when the
pressed?
Does voltage on the positive and negative terminals of slide
motor change when the
Replace the slide motor.
Yes
Yes
Yes
No
Yes
or
button is
Yes
or
button is pressed?
Yes
Check soldering joint and parts of pins 24 and 25 of IC1201, and
No
peripheral circuit.
Check soldering joint of PWB of completed IC1601 and CNP1601
No
disc motor.
Check the soldering joint of pins 20 and 21 of IC1201, IC1601,
No
IC1601, CNS1101.
Check the waveform on the pins 22 and 23 of IC1201, check the
Yes
peripheral parts and soldering joint.
Check the waveform on the pins 22 and 23 of IC1201, check the
No
peripheral parts and soldering joint.
Check the soldering joint of IC1601 and CNP1602.
No
Check the soldering joint connected to the slide motor to see
No
whether there is wire breakage.