INSTALLATION
Continued
BUILT-IN FIREpLACE
INSTALLATION
Built-in installation of this fireplace involves
installing fireplace into a framed-in enclosure.
This makes the front of fireplace flush with wall.
If installing a mantel above the fireplace, you
must follow the clearances shown in Figure
17, page 13. Follow the instructions below to
install the fireplace in this manner.
Height
Front Width
Depth
WARNING: A qualified electri-
cian must connect electrical wiring
to duplex outlet for built-in instal-
lation. Follow all local codes.
1. Frame in rough opening. Use dimensions
shown in Figure 12 for the rough opening.
If installing in a corner, use dimensions
shown in Figure 13 for the rough opening.
The height is 33" which is the same as the
wall opening above.
33"
Figure 12 - Rough Opening for Installing
39
"
3
/
8
55
Figure 13 - Rough Opening for Installing
in Corner
121308-01E
Actual
Framing
32
/
"
33"
3
8
34
/
"
35
5
16
16
/
"
17
11
16
17
3
/
"
4
35
1
/
"
8
in Wall
35
"
1
/
8
"
5
/
8
www.desatech.com
2. If using blower, install duplex outlet to the
right support bracket in the bottom of firebox
(see Figure 14). See Accessories, page 31.
If not using blower, go to step 7.
3. Route wires from electrical box through
smallest hole in outer casing using strain
relief fitting provided (see Figure 14).
4. Connect wires from the electrical box to
duplex outlet. Match wire colors to those
indicated on duplex outlet. Be sure to
connect ground wire.
5. Install shield to end of right support
bracket and behind the firebox wrapper
with 2 screws provided (see Figure 15,
page 12).
/
"
1
6. Plug blower cord into duplex outlet.
8
7. Replace bottom of firebox and reconnect
/
"
3
4
remote receiver module to valve.
8. Install gas piping to fireplace location. This
installation includes an approved flexible
gas line (if allowed by local codes) after
the equipment shutoff valve. The flexible
gas line must be the last item installed on
the gas piping. See Installing Gas Piping
to Fireplace Location, page 13.
9. Carefully set fireplace in front of rough
opening with back of fireplace inside wall
opening.
10. Attach flexible gas line to gas supply.
See Connecting Fireplace to Gas Supply,
page 15.
Blower
Power Cord
27
"
7
/
8
Figure 14 - Connecting Duplex Outlet
Cable from
Blower
Electrical Source
Screw
Duplex
Outlet
Support
Bracket
Strain
Relief
Fitting
11