Download Print this page

Emerson White Rodgers 1F95-0680 Installation And Operating Instructions Manual page 11

Blue commercial thermostat with automatic heat/cool changeover option and damper control

Advertisement

Energy Saving Factory Pre-Program
The 1F95-0680 thermostats are programmed with the energy saving settings shown in the table below for all days of the week.
If this program suits your needs, simply set the thermostat clock and press the RunSched button.
The table below shows the factory set heating and cooling schedule for all days of the week.
Heating
6:00 AM
Program
Cooling
6:00 AM
Program
* You can eliminate these two program periods in the configuration menu (reference #15) if the building is occupied all day.
Day period will change to 6:00 AM and 70° and can be programmed as required.
Planning Your Program – Important
The Heating and Cooling Program schedules below allow you to pencil in your own program times and temperatures.
The 1F95-0680 comes configured for 7 day programming and can also be configured for 5+1+1 programming (see configura-
tion section).
Factory settings are listed on Monday, Saturday and Sunday. If you are re-programming a 5+1+1 day schedule, pencil in your
own times and temperatures directly below the factory times and temperatures.
If you are re-programming a 7 day schedule, fill in all lines with the times and temperatures you want.
Keep the following guidelines in mind when planning your program.
• In Heating, lower temperatures will save energy.
• In Cooling, higher temperatures will save energy.
• If you plan on using Auto Changeover, do not program the heating temperature higher than the cooling temperature.
Worksheet for Re-Programming 5+1+1 and 7 Day Program
Heating
Wake Up
Program
(Morn)
6:00 AM
MON
TUE
WED
THU
FRI
6:00 AM
SAT
6:00 AM
SUN
Cooling
Wake Up
Program
(Morn)
6:00 AM
MON
TUE
WED
THU
FRI
6:00 AM
SAT
6:00 AM
SUN
* Wake Up
Leave For Work
(Morn)
(Day)
70°F
8:00 AM
75°F
8:00 AM
Leave For Work
(Day)
Fan
70°F
Auto 8:00 AM
62°F
70°F
Auto 8:00 AM
62°F
70°F
Auto 8:00 AM
62°F
Leave For Work
(Day)
Fan
75°F
Auto 8:00 AM
83°F
75°F
Auto 8:00 AM
83°F
75°F
Auto 8:00 AM
83°F
* Return Home
(Eve)
62°F
5:00 PM
70°F
83°F
5:00 PM
75°F
Return Home
(Eve)
Fan
Auto 5:00 PM
70°F
Auto 5:00 PM
70°F
Auto 5:00 PM
70°F
Return Home
(Eve)
Fan
Auto 5:00 PM
75°F
Auto 5:00 PM
75°F
Auto 5:00 PM
75°F
PROGRAMMING
Go To Bed
(Night)
10:00 PM
62°F
10:00 PM
78°F
Go To Bed
(Night)
Fan
Fan
Auto 10:00 PM
62°F
Auto
Auto 10:00 PM
62°F
Auto
Auto 10:00 PM
62°F
Auto
Go To Bed
(Night)
Fan
Fan
Auto 10:00 PM
78°F
Auto
Auto 10:00 PM
78°F
Auto
Auto 10:00 PM
78°F
Auto
11

Hide quick links:

Advertisement

loading