SPECIFICATIONS
Electrical Rating:
Battery Power ..................................... mV to 30 VAC, NEC Class II, 50/60 Hz
Input-Hardwire .................................... 20 to 30 VAC, NEC Class II, 50/60 Hz
Terminal Load .......................................... 1.5 A per terminal, 2.5A maximum all terminals combined
Setpoint Range ........................................ 45° to 99° F (7° to 37° C)
Rated Differentials (@ 6°F/ Hr):
Fast
Heat (Conventional Gas / Oil / Elect) ..... 0.5°F
Cool (Central Air) ................................. 0.9°F
Heat Pump (Heat and Cool) ................ 0.9°F
Heat Pump Aux. .................................. 0.5°F
Operating Ambient .................................. 32°F to +105°F (0° to +41°C)
Display Temperature Range ....................... 32°F to +99°F (0 to 37°C)
Operating Humidity ................................. 90% non-condensing maximum
Shipping Temperature Range ................... -20°F to + 150°F (-29° to +65°C)
Thermostat Dimensions ........................... 3-3/4" H x 6" W x 1-1/8" D
white-rodgers.com
emersonclimate.com
1F85U-42PR (Programmable)
Installation and Operating Instructions
Universal Thermostat
Battery Powered or Hardwired with Common
Optional Accessory: Wall
Cover-Up Plate F61-2663,
6 3/4" W x 4 1/2" H
Maximum
Thermostat Applications
Stages
Heat/ Cool
Conventional Gas, Oil, Electric
(mV and 24V), Heat only, Cool only or
Heat/Cool Systems
Heat Pump (Air Source or Geothermal)
with Aux. Heat
MERCURY NOTICE: This product does not contain
mercury. However, this product may replace a product
that contains mercury. Mercury and products containing
mercury must not be discarded in household trash.
Refer to www.thermostat-recycle.org for information
on disposing of products containing mercury.
Med
Slow
0.75°F
1.9°F
1.2°F
1.7°F
1.2°F
1.7°F
0.75°F
1.9°F
PART NO. 37-7554D
Replaces 37-7554C
2/2
4/2
1652

Advertisement

Table of Contents
loading

Summary of Contents for Emerson 1F85U-42PR

  • Page 1 1F85U-42PR (Programmable) Installation and Operating Instructions Universal Thermostat Battery Powered or Hardwired with Common Programming made Simple See page 7 Optional Accessory: Wall Cover-Up Plate F61-2663, 6 3/4” W x 4 1/2” H INDEX Thermostat Installation Maximum Thermostat Applications Stages...
  • Page 2: Thermostat Installation

    THERMOSTAT INSTALLATION WIRING Refer to equipment manufacturer’s instructions for specific system wiring information. After wiring, see INSTALLER MENU for proper thermostat configuration. Wiring table shown are for typical systems and describe the thermostat terminal functions. Wiring will change when dedicated emergency heat is on (See Installer menu #15).
  • Page 3: Installer Menu

    RC/RH Jumper Wire This thermostat electrically connects the RC and RH terminals so a jumper wire is not required. If the application provides a separate wire for RC and RH, clip the RC/RH jumper. This will isolate both terminals so they can be independently used.
  • Page 4: Test Equipment

    INSTALLER MENU (C0ntinued) Settings Installer’s Menu # Default Setting Description (flashing icons) (Hold Menu 8 Seconds) (Press 7 – 7 Day Schedule Type: set as either 7-Day, 5 – 5-1-1 Day 5-1-1 Day or Non-Programmable 0 – Non Programmable 2 -leave, return Defines periods per day 4 -wake, leave, return, sleep Early Start: starts heating or...
  • Page 5 USING THE THERMOSTAT THERMOSTAT OVERVIEW Before you begin using your thermostat, you should be familiar with its features, display and the location/operation of the thermostat buttons and switches. THERMOSTAT BUTTONS THE DISPLAY AND SWITCHES 1.) Fan Button 8.) Next (Menu button) is used to navigate within a menu 2.) Hold a permanent temperature or 9.) Set the correct time, access the schedule and customize press again to cancel hold (return to...
  • Page 6: Thermostat Operation

    USER MENU To customize thermostat settings, press the Menu button from the home screen. Use the buttons to highlight Settings and press Next. Use Next and Back to navigate through menu items. Press to change the setting. User’s Menu # Default Setting Settings (Press Menu button...
  • Page 7: Troubleshooting

    THERMOSTAT SCHEDULE / PROGRAMMING For tips on programming your thermostat to receive optimal comfort, convenience and energy savings go to: thermostathelper.com Energy Saving Factory Schedule This thermostat is programmed with the energy saving settings shown in the table below for all days of the week.
  • Page 8 WARNING: This product contains a chemical known to the state of California to cause cancer and birth defects and other reproductive harm. HOMEOWNER HELP LINE: 1-800-284-2925 White-Rodgers is a business of Emerson Electric Co. The Emerson logo is a trademark and service mark white-rodgers.com of Emerson Electric Co. emerson.com...

Table of Contents