Quick Search - Uniden BCD325P2-AU Owner's Manual

Table of Contents

Advertisement

3.
At 'Select Store Sys' scroll to the conventional system you want to store the
frequencies in and press E/yes.
4.
At 'Select Range' scroll to the 'service search' or to 'custom search' to select
where to search from and press E/yes.
Note: The quick key for the system must be turned on (if one is assigned to
the system) and not locked out to select the system to store frequencies in
otherwise you will see 'Nothing to Scan'. If no systems are programmed 'No
System Stored' appears.
When you have selected a service search or custom search range(s), the scanner
looks for active frequencies within the range(s) and 'Search and Store' appears on
the display's lower line and the system name and search range name(s) appear on
the display's upper line. When the scanner finds an active transmission, it checks to
see if the frequency has already been stored in the system ('Memory Check' in the
display). If the frequency has already been stored, the scanner continues to search.
If the frequency has not been stored, it stores the frequency into a (created) group
named 'Found Channels', then resumes searching. 'Limit Reached' will appear in the
display when the Max Auto Store value is reached.
To Auto Store IDs, press Menu.
1.
Scroll to 'Search for...' and press E/yes.
2.
Scroll to 'Search and Store' and press E/yes.
3.
At 'Select Store Sys' scroll to the trunked system you want to store the IDs
in and press
E/yes.
4.
At 'Select Site' scroll to the site you want to store the IDs in and press E/yes.
Note: The quick key for the system must be turned on (if one is assigned to
the site) and not locked out to select the system to store IDs in otherwise
you will see 'Nothing to Scan'. If no systems are programmed, 'No System
Stored' appears. Search and store does not work if an EDACS SCAT system is
selected.
'ID Search and Store' appears on the display's lower line and the system name
appears on the display's upper line. When the scanner finds an active transmission,
it checks to see if the ID has already been stored in the system ('Memory Check'
in the display). If the ID has already been stored, the scanner continues to search.
If the ID has not been stored, it stores the ID into a (created) group named 'Found
Channels', then resumes searching. 'Limit Reached' will appear in the display when
the Max Auto Store value is reached.

Quick Search

Quick Search allows you search from the currently-tuned frequency if you are
scanning, or enter a frequency to start searching from. Quick Search will search all
the way up to 960 MHz or all the way down to 25 MHz then start over.
99

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bcd325p2

Table of Contents