5. Type: cp /mnt/linux/40002086_M.src.rpm /usr/src/packages/SOURCES
6. Type: umount /mnt
7. Type: cd /usr/src/packages/SOURCES
8. Type: rpmbuild --rebuild 40002086_M.src.rpm
9. Type: rpm -i /usr/src/packages/RPMS/ppc64/dgrp-1.9-6.ppc64.rpm
10. Type: rpm -qa | grep dgr
If the Digi RealPort Package installed correctly, the following is an example of the return message:
dgr-1.9.6
11. Afer the Digi RealPort software is installed, the user may configure the 7036-P16 onto the network, if
it is not already configured. For instructions on how to perform the network configuration, see
"Configuring the 7036-P16 into the network" on page 100.

Configuring the 7036-P16 device and tty

You might need to configure the 7036-P16 as a serial device on a host server. Use the procedure in this
section to perform this task.
The task consists of the following steps:
1. Configure the 7036-P16 as a serial device on a host server installed with one of the following
operating systems:
v AIX 5L 5.2.0.75, or later
v AIX 5L 5.3.0.30, or later
v Red Hat Enterprise Linux version 4, Update 3, or later
v SUSE Linux Enterprise Server 9, SP2, or later
This in effect binds the 7036-P16 to the host server.
2. Configure 7036-P16 system ports for use with Digi RealPort software.
Configuring a 7036-P16 device on an AIX host server
Assumptions:
v The target 7036-P16 and the host server are configured on an Ethernet network.
v The target 7036-P16 and the host server are attached to an Ethernet network.
v The Digi RealPort software is installed on the server.
Gather the following information:
v IP Address of the target 7036-P16: [7036-P16 IP Address]
v IP Address of the host server: [Host Server IP Address]
v Root password of target 7036-P16
Configure the 7036-P16 as a serial device on an AIX server:
1. Ensure that the 7036-P16 and the server are on the network. Ping the 7036-P16 by typing the
following command: ping -c 1 [IP Address of target 7036-P16]
If the 7036-P16 responds to the ping, then it is on the network and the user can proceed to the next
step. If the 7036-P16 does not respond to the ping, then the 7036-P16 is not on the network and the
user must perform the network configuration procedure, see "Configuring the 7036-P16 into the
network" on page 100.
2. Ensure that the Digi RealPort Software is installed on the server. Type the following command: lslpp
-l | grep digi
The response indicates that the digiasync.realport.obj file is installed.