3. Ice Purge Cycle Bypass

To speed up the diagnostic process, the 5-min. ice purge cycle may be bypassed
by pressing the "SERVICE" button on the control board after the gear motor starts.
WARNING! Risk of electric shock. Care should be taken not to touch live terminals.
B. Controls and Adjustments
Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact your
Hoshizaki Certified Service Representative.

1. Default Dip Switch Settings

The S1 dip switch settings are factory-set to the following positions:
Model
FS-1001MLH-C
FS-1022MLH-C
FS-1500MLH-C
NOTICE
S1 Dip Switch
S1 Dip Switch No.
1
2
3
4
ON
OFF OFF OFF OFF OFF
Normally off (factory use)
Bin Control Shutdown Delay (BC (mechanical stand-alone))
Bin Control Selector
Continuous Dispensing Timer
(DCM models only, do not adjust on modular icemakers)
Drain Frequency Control
Bin Control Shutdown Delay (BC1 (infrared sensor))
39
5
6
7
8
ON
ON
9
10
OFF OFF

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fs-1022mlh-cFs-1500mlh-cSrc-10hFs-1001mlh-c