Infinity iW-1240 RDM Manual page 45

Table of Contents

Advertisement

Infinity iW-1240 RDM
Problem
Probable cause(s)
One or more
No power to the fixture
fixtures do not
function at all
Primary fuse blown
Fixtures reset
The controller is not connected.
correctly, but all
3-pin/5-pin XLR Out of the
respond
controller does not match XLR Out
erratically or not
of the first fixture on the link (i.e.
at all to the
signal is reversed)
controller
Poor data quality
Bad data link connection
Fixtures reset
correctly, but
Data link not terminated with 120
some respond
Ohm termination plug
erratically or not
Incorrect addressing of the fixtures
at all to the
controller
One of the fixtures is defective and
disturbs data transmission on the
link
3-pin/5-pin XLR Out on the fixtures
does not match (pins 2 and 3
reversed)
The color wheel, gobo wheel or a
Shutter closes
gobo has lost its index position and
suddenly
the fixture is resetting the effect.
Fixture is too hot
No light or LEDs
cut out
intermittently
LEDs are damaged
The power supply settings do not
match local AC voltage and
frequency
Ordercode: 41527
Solution
Check if power is switched on
and cables are plugged in
Replace fuse
Connect controller
Install a phase reversing cable
between the controller and the
first fixture on the link
Check data quality. If much lower
than 100 percent, the problem
may be a bad data link
connection, poor quality or
broken cables, missing
termination plug, or a defective
fixture disturbing the link
Inspect connections and cables.
Correct poor connections. Repair
or replace damaged cables
Insert termination plug in output
jack of the last fixture on the link
Check address setting
Bypass one fixture at a time until
normal operation is restored:
unplug both connectors and
connect them directly together.
Have the defective fixture
serviced by a qualified technician
Install a phase-reversing cable
between the fixtures or swap pin 2
and 3 in the fixture that behaves
erratically
Contact a technician for
servicing, if the problem persists.
Allow the fixture to cool down
Clean the fan
Make sure air vents and the front
lens are not blocked
Turn up the air conditioning
Disconnect the fixture and return
to your dealer
Disconnect fixture. Check settings
and correct if necessary
44

Advertisement

Table of Contents
loading

This manual is also suitable for:

41527