Framing Dimensions - Superior Fireplaces WCT6820 Installation And Operation Instruction Manual

Table of Contents

Advertisement

FRAMING DIMENSIONS

Fireplace Opening Width
A
36-1/4"
921 mm
B
42"
1067 mm
C
30-1/8"
764 mm
D
13-1/2"
343 mm
E
77"
1956 mm
F
37-1/2"
953 mm
G
*24-1/2"
603 mm
J
53-3/4"
1365 mm
K
8"
203 mm
L
1"
25 mm
* Total depth is 25 inches (635mm) including the
back spacer minus 1/2 inch (13mm) for drywall
to be flush with the facing.
Combustion Air Kit
K
K (allow space when framing)
Notes
Diagrams, illustrations and photo-
graphs are not to scale – consult
installation instructions. Product
designs, materials, dimensions,
specifications, colors and prices are
subject to change or discontinuance
without notice.
All framing dimensions calculated for
1/2" dry wall at the fireplace face. If
sheathing the chase or finishing with
other thickness materials, calcula-
tions will need to be made.
* The fireplace must not be in
contact with any insulation or loose
filling material. Cover the insulation
with Drywall panels around the
fireplace.
17-3/4"
3-1/4"
6-3/4
8-1/4"
24"
Left Side View
Figure 8 - Framing Dimensions
Back Wall of Chase/Enclosure
Including Finising Materials if any
* Zero Clearance
From Back
Spacer to Wall
Rough Framing Face (Unfinished Shown)
Combustible materials can NOT
be used in the space directly
above the fireplace. Do not fill
the space above the fireplace
with any material (Except the
wood framing)
7'
Min.
B
(dimension includes finish
material inside framing, if any)
28-1/8"
9-3/4"
22-5/8"
**
Top View
42"
12-1/4"
22-1/2"
36"
Front View
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
OUTSIDE CHASE
Corner Installation
C
F
G
A
2 x 3
Min.
Plywood 1/2"
G
Facing
Rough Framing Face
The facade must be removable
once installed. The facade is
1"
designed to overlap any facing
material installed on the front of
the fireplace. If thicker material
10-3/8"
14"
is installed, use the facade as a
24"
template and make sure it can be
easily removed for servicing.
**Gravity Vent Outlets
36-1/8"
12-3/4
15-1/2"
Right Side View
19-5/8"
D
20-1/2"
E
B
A
Fireplace Framing
IMPORTANT
1. Combustible material must
be installed flush with the
fireplace. It may not project
in front of and on the fire-
place (i.e. the steel facade
of the fireplace) (Figure 12).
2. Non-combustible materials
such as brick, stone or ce-
ramic tile may project in front
17-3/4"
of and onto the fireplace
facing (Figure 13).
3-3/4
J
Header
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wct6820ws

Table of Contents