SET GAS PRESSURE:
Gas pressure regulator is factory set.
SET PILOT FLAME:
Remove all burner control knobs, then remove the front panel.
Remove grates.
The pilot adjustments are near the control valve for each set of
burners.
Using a small, flat-blade screwdriver, turn the screw clockwise to
decrease the flame size, or counter-clockwise to increase the flame
size.
Adjust the pilot flame to 1/4" high. Test for operation: all sections
of the burner must light without undue delay. Drafty conditions may
require a higher flame to allow the pilot to remain lit.
Replace the grates, front panel and all knobs before returning the
unit to service.
ADJUST BURNER FLAME:
Remove all burner control knobs, then remove the front panel.
Remove grates and radiants.
Turn an individual burner on.
Loosen the locking screw on the shutter.
Turn the shutter to admit more or less air as required. Adjust the
air shutter until the flame is mostly blue in color.
Tighten the locking screw when finished. Replace tall grates and
radiants, the front panel and all knobs before returning the unit to
service.
BURNER
FLAME
ADJUST
LESS
AI R
SHUTTER
MORE AI R
LOCKI NG
SCREW
BURNER
CONTROL
KNOB
Fig. 3 Adj ust ment s
PI LOT
FLAME
ADJ UST
LESS
FLAME
O N
MORE
FLAME
PILOT
FLAME
ADJUST
I L2286
7
IMPORTANT:
Adjustments must be performed
by a qualified technician only.
IMPORTANT:
The appliance is shipped from
the factory equipped for natural
gas and adjusted for sea level
to 2000 feet elevation. For
conversion to LP / Propane,
or for operation above 2000
feet elevation, contact your
Authorized Wells Service
Agency.