OPERATION
2.
Purge Bulb
Pump purge bulb (B) until fuel is
visible in the "Clear" fuel return
line. Pump bulb an additional 4
or 5 times.
3.
Recoil Starter
Lay the unit on a flat area and
keep movable attachment parts
clear of all obstacles. Firmly grip
throttle handle and throttle
trigger lockout with left hand.
Rapidly pull recoil starter
handle/rope (D) until engine
fires.
Note: If engine does not start after 5 pulls, use Cold Start
Procedure.

Stopping Engine

1.
Throttle
Release throttle trigger and
allow engine to return to idle
before shutting off engine.
2.
Stop Switch
Move stop switch button (A)
backward to STOP position.
If engine does not stop when stop switch is moved to STOP
position, close choke - COLD START position - to stall engine.
Have your ECHO dealer repair stop switch before using unit
again.