TABLE OF CONTENTS

Important Safety Information ............................................................................................................4
Product Features .............................................................................................................................. 6
Air For Combustion and Ventilation .................................................................................................. 8
Installation ...................................................................................................................................... 11
Operation ........................................................................................................................................ 18
Care and Maintenance ................................................................................................................... 22
Troubleshooting .............................................................................................................................. 23
Replacement Parts ......................................................................................................................... 27
Warranty ......................................................................................................................................... 28
WARNING: Read the Installation & Operating Instructions before using this appliance.
IMPORTANT: Read all instructions and warnings carefully before starting installation.
Failure to follow these instructions may result in possible injury to persons or a fire
hazard and will void the warranty.
PRODUCT SPECIFICATIONS
SERIES
MAX BTU
Fuel Type
Ignition
Manifold Pressure
Inlet Gas Pressure
Maximum
*Minimum (*For purposes of input adjustment) 11 in. W.C.
Dimensions (in.)
( H x W x D)
Fan Ratings (Select Models)
SERIES
MAX BTU
Fuel Type
Ignition
Manifold Pressure
Inlet Gas Pressure
Maximum
*Minimum (*For purposes of input adjustment) 11 in. W.C.
Dimensions (in.)
( H x W x D)
Fan Ratings (Select Models)
IR6PTDG-1/PMDG-1
6,000
Propane
Electronic Push Button
10 in. W.C.
14 in. W.C.
20.00 in. x 17.32 in. x 9.49 in.
Not Available
IR18PTDG-1/PMDG-1
18,000
Propane
Electronic Push Button
10 in. W.C.
14 in. W.C.
24.02 in. x 20.94 in. x 10.08 in.
120V/60Hz,18W, 0.15A
2
IR12PTDG-1/PMDG-1
12,000
Propane
Electronic Push Button
10 in. W.C.
14 in. W.C.
11 in. W.C.
20.00 in. x 17.32 in. x 9.49 in.
120V/60Hz,18W, 0.15A
IR30PTDG-1/PMDG-1
30,000
Propane
Electronic Push Button
10 in. W.C.
14 in. W.C.
11 in. W.C.
24.09 in. x 28.07 in. x 10.51 in.
120V/60Hz,18W, 0.15A