Dyna-Glo WK95C6C Owner's Manual

Dyna-Glo WK95C6C Owner's Manual

Portable kerosene-heater
Hide thumbs Also See for WK95C6C:

Advertisement

KE ROSE NE -HE ATE R
"OWNER'S MANUAL"
Before the first use of this heater, please read this OWNER'S MANUAL very
carefully. This OWNER'S MANUAL has been designed to instruct you as to the
proper manner in which to assemble the heater, maintain the heater, store the
heater, and most importantly, how to operate the heater in a safe and efficient
manner, please keep this manual for future reference.
4221 - 0082-03
04/14 Rev.00
POR TABLE
MODEL : WK95C6C
GHP Group, Inc.,
Niles, IL 60714-3302, USA
TELEPHONE : 1-877-447-4768
IMWK23WM-GCU

Advertisement

Table of Contents
loading

Summary of Contents for Dyna-Glo WK95C6C

  • Page 1 POR TABLE KE ROSE NE -HE ATE R “OWNER’S MANUAL” MODEL : WK95C6C Before the first use of this heater, please read this OWNER'S MANUAL very carefully. This OWNER'S MANUAL has been designed to instruct you as to the proper manner in which to assemble the heater, maintain the heater, store the heater, and most importantly, how to operate the heater in a safe and efficient manner, please keep this manual for future reference.
  • Page 2: Cautions-Safety Guide

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! CAUTIONS - SAFETY GUIDE - OPERATE THIS KEROSENE HEATER ACCORDING WARNING!! RISK OF EXPLOSION / RISK OF FIRE TO MANUFACTURER’S INSTRUCTIONS MAY use any fuel other than water-clear 1-K ! NEVER RESULT IN CONDITIONS WHICH CAN PRODUCE kerosene or red dyed 1-K kerosene.
  • Page 3: Table Of Contents

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! CONTENTS OF OWNER'S MANUAL ITEM PAGE ITEM PAGE CAUTIONS-SAFETY GUIDE CARBON REMOVAL / DRY BURNING INTRODUCTION WICK ASSEMBLY FEATURES 9~11 WICK REPLACEMENT UNPACKING AND ASSEMBLY EXTINGUISHING THE HEATER KEROSENE (1-K ONLY) 12~13 AUTOMATIC SAFETY SHUT-OFF DEVICE FUELING YOUR HEATER LONG TERM STORAGE OF YOUR HEATER AUTOMATIC IGNITION SYSTEM...
  • Page 4: Unpacking And Assembly

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! UNPACKING AND ASSEMBLY CAUTION: "RISK OF BURNS" DO NOT OPERATE HEATER WITHOUT INSTALLING THE PROTECTIVE GUARD OR GRILL. 1. REMOVE THE HEATER AND ALL PACKING MATERIALS FROM THE BOX. (Fig.2) NOTE : Save the shipping carton and packing materials for future storage.
  • Page 5: Kerosene (1-K Only)

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! D) INSTALLING CARRYING HANDLE: (Fig.6) Insert the carrying handle into the holes on the cabinet by aligning holes on brackets of top plate. E) INSTALLING TOP GUARD: (Fig.7) Align the 2 brackets on the top guard with the 2 mounting brackets on the front and rear guards.
  • Page 6: Fueling Your Heater

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! It is normal for a kerosene heater to give off a slight odor upon start-up and shut-down. After 5-10 minutes of operation, the heater should have reached its normal operating temperature and any odor should be very slight.
  • Page 7: Automatic Ignition System

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! AUTOMATIC IGNITION SYSTEM For safety and convenience, this heater features an automatic ignition system. 2 "C" cell batteries, included with the heater, provide the power for the igniter which lights the wick once it has been raised to its maximum height.
  • Page 8: Checking The Ignition System

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! CHECKING THE IGNITION SYSTEM If the automatic ignition system fails to operate properly, perform the following checks: Igniter BATTERIES -2 "C" cell batteries are located at the rear of the heater. Replace with new batteries. Fig.15 IGNITER PLUG - If the automatic ignition system still doesn't work after replacing the batteries, check the igniter plug.
  • Page 9: Wick Maintenance

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NOTE : During start-up, small adjustments to the flame can be performed by using the burner knob on the front of the burner and MOVING THE BURNER FROM SIDE TO SIDE until the flame at the top of burner is as even as possible.
  • Page 10: Wick Assembly

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! WICK ASSEMBLY- Check at least once a month!! The burner assembly sits on top of the wick guide. Over time, tar deposits can accumulate on the wick guide, and this can prevent the burner assembly from seating properly.
  • Page 11 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! . Remove the four wing nuts . Replace the wick adjustment knob temporarily. which hold the wick assembly Turn the knob CLOCKWISE to raise the wick. to the heater and carefully lift the wick assembly from the heater.
  • Page 12 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! .Turn the wick assembly upside down to replace the wick cover. . Align the tabs on the wick cover with the four screw holes on the bottom of the assembly, as shown, and snap it into place.
  • Page 13: Extinguishing The Heater

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! EXTINGUISHING THE HEATER To extinguish the heater, push down on the manual shut-off knob (Fig.18) with one hand while holding the wick adjuster knob in the other hand. You will feel the pressure of spring action attempting to turn the wick adjuster knob in a counter- clockwise direction in your hand.
  • Page 14: Long Term Storage Of Your Heater

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! TESTING THE SAFETY SHUT-OFF DEVICE : At least once a week during the heating season, it is important to test the safety shut-off device to be sure that it is operating properly. WITH THE HEATER TURNED OFF, raise the wick using the wick adjuster knob to the fully raised position.
  • Page 15: Trouble Shooting Guide

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! TROUBLE SHOOTING GUIDE Heater Will Not Light ; 1. Fuel tank is empty 1. Fill tank with water-clear 1-K kerosene or 2. Water present in kerosene red dyed 1-K kerosene. 2. Drain tank. Remove wick assembly & replace wick. Reinstall wick assembly.
  • Page 16: Parts List

    WS-CV17 2113-0032-00 WICK ADJUSTER ASS'Y (COMPLETE) WICK See Below WICK ADJUSTER GASKET PS-CV19R See 9 SAFETY SHUT OFF DEVICE DRIP TRAY ASS'Y(WK95C6C) PS-CV32R1B FUEL CAP GASKET WS-CV30 FUEL CAP ASS'Y WS-CV29 WICK ADJUSTER KNOB(WK95C6C) WS-CV14B BATTERY CASE ASS'Y(WK95C6C) WS-CV27R1B FRONT GRILLE...
  • Page 18 GHP Group, Inc. 6440 W Howard St Niles, IL 60714-3302 Tel: (877) 447-4768 www.ghpgroupinc.com GHP Group, Inc. 6440 W Howard St Niles, IL 60714-3302...

This manual is also suitable for:

Rmc- 95c6Rmc- 95c6b