Download Print this page

Advertisement

Quick Links

360 Herndon Parkway
Suite 1400
Herndon, VA 20170
http://www.rheintech.com
APPENDIX I:
MANUAL
Scanning Receiver Certification Report
Alinco, Inc.
Rev: 1 3/21/02
FCC ID: PH3DJ-296T
Work Order: 2002032 / QRTL02-151DF
Page 26

Advertisement

loading

Summary of Contents for Alinco DJ296

  • Page 1: Appendix I: Manual

    360 Herndon Parkway Suite 1400 Herndon, VA 20170 http://www.rheintech.com APPENDIX I: MANUAL Scanning Receiver Certification Report Page 26 Alinco, Inc. FCC ID: PH3DJ-296T Work Order: 2002032 / QRTL02-151DF Rev: 1 3/21/02...
  • Page 2 DJ296 INSTRUCTION MANUAL 1. INNOVATIVE AND NEW FEATURES . Comes equipped 39 CTCSS Tone Squelch function. . Comes equipped 104DCS Digital code squelch function. . TOT (Time Out Timer) can be set to a Duty Cycle most accommodating to the user’s requirements.
  • Page 3: Dtmf Keypad

    3. CONTROLS/FUNCTIONS Top, Front, Sides and Rear View 1. LCD DISPLAY PANEL Refer to LCD Display section of this manual. 2. MAIN TUNING DIAL The main tuning dial/knob may be rotated in either direction to select RX/TX frequency and volume/squelch level. 3.
  • Page 4 4. LCD Display 1. F When the F icon appears, secondary function keys may be activated. 2. + It indicated the plus or minus offset direction. 3. T It appears when the tone encoder is activated. 4. TSQ It appears when the tone squelch is activated. 5.
  • Page 5 Operation Manual DJ296 Contents 5 Operation 1(Basics) 5-1 Adjusting the Volume 5-2 Adjusting the Squelch 5-3 Receiving 5-4 Transmitting 5-5 Frequency Selection 5-6 Channel Step 5-7 Shift Direction and Offset Frequency 5-8 Memory Channel Operation 5-9 CALL Channel Operation 5-10 Scanning...
  • Page 6 5 Operation 1 (Basics) 5-1 Adjusting the Volume . [VOL] appears on LCD when VOL key is pressed, volume level is displayed. The initial value is 00 (minimum). The volume can be increased or decreased by rotating the dial. The maximum value is 20. There are 21 steps from 00-20 in volume adjustment.
  • Page 7 [UP/DOWN with channel step] 1. Rotating the dial clockwise increases frequency 1 channel step/1 click, and rotating counterclockwise decreases the frequency 1 channel step/1 click. [1MHz UP/DOWN] 1. Press the [F] key then rotate the dial while [F] icon is ON, the frequency increases or decreases by 1MHz depending on the direction of the rotation.
  • Page 8 width may be compensated. 5-7 Shift Direction and Offset Frequency Usually the repeater is used in the duplex mode. Namely the signal received with a certain frequency is transmitted with another frequency. The difference between these frequencies is the offset frequency. The setting range of the offset frequency is from 0 to 99.995MHz.
  • Page 9 When the memory channel is programmed, [M] appears on the LCD. 3. Press and hold the FUNC key, then press MW key while [F] icon is ON. A beep sounds, and the programmed frequency will be erased. Then [M] starts flashing. 4.
  • Page 10 (1) VFO SCAN 1. Press the V/M key to enter VFO mode. 2. Press the SCAN key to start scanning. The decimal point of the frequency on the LCD starts flashing to indicate the scanning is started. The unit scans by a channel step to the last direction of operation. 3.
  • Page 11 When tone and DCS are set, the signal will be transmitted with tone frequency and DCS code. 5-14 Auto Power Off Function The function prevents the battery from consuming when you forget to turn off the power switch. (1) Setting Press and hold the F key, then press 6/APO key while F icon is ON.
  • Page 12 In the unlikely event that CPU clock noise is present on a particular operating frequency programmed into the radio, you can shift the CPU clock frequency to avoid the CPU clock noise, which normally is so weak that it is inaudible even if the radio is tuned exactly to its frequency.
  • Page 13 Changing both of tone encoder/tone decoder frequencies 1. Set the tone encoder in the tone squelch setting mode. (T icon is ON.) Change the tone encoder frequency with dialing, then the setting is completed. 2. When memory is programmed in this mode, the current tone frequency will be programmed to both of encoder frequency and decoder frequency.
  • Page 14 6 digits are displayed, and nothing appears at first. 2. Select the dialer memory NO. with the dial. 3. For example, when you input 1 2 3 4 5 6 7 8 9, the LCD displays as shown below: 1] - [ 1 2] - [ 1 2 3 ] - [ 1 2 3 4 ] - [ 1 2 3 4 5 6 ] - [ 2 3 4 5 6 7 ] - [ 3 4 5 6 7 8 ] - [ 4 5 6 7 8 9 ] 4.
  • Page 15 1. When the DTMF code is transmitted using the auto dialer, the code is transmitted with programmed burst/ pause time. The initial setting is 60ms. DTMF first digit's burst time 2. When the DTMF code is transmitted using the auto dialer, the code will be transmitted at the programmed first digit burst time.
  • Page 16 6-12 TOT Penalty Function When the transmission is completed by the TOT function, the transmission will be inhibited within the programmed TOT Penalty time. The transmission is inhibited during the penalty time. 1. TOT Penalty function and its penalty time can be programmed in the set mode. If the PTT key is pressed during the TOT Penalty time, an alarm tone will sound.
  • Page 17: Set Mode

    If data transfer is failed, "PASS" does not appear on the LCD. Try again from the first. 7-2 Burglary Alarm Function If someone tries to steal your transceiver, an alarm goes off from the speaker. Setting Be sure to set the battery pack. 1.
  • Page 18 1. [BS-ON] appears on the LCD. 2. Rotate the dial, and the display toggles as shown below. Then ON and OFF are switched repeatedly. ..downward upward….. ……BS-ON - BS-OF ………. …………………………………. [No.2] Scan Type Selection 1. [TIMER] appears on the LCD. 2.
  • Page 19 The setting is available up to max. 15 seconds. [No.8] DTMF WAIT time 1. [DWT-01] appears on the LCD. 2. Rotate the dial, and the display toggles as shown below. Then the DTMF WAIT time will be changed. 3. ** shows the current DTMF WAIT time. The initial setting is 0.1 second, and [DWT-01] appears on the LCD.
  • Page 20: Reset Function

    …………MRS-OF …..MRS-ON……….. …………………………………………… 9 RESET Function Press and hold the F key, then turn on the power. The unit returns to the factory's default setting. …………………………………………………………………………………………………….. VFO frequency 223.500MHz CALL frequency 223.500MHz Memory channel a blank SHIFT setting none SHIFT frequency 1.6MHz Channel step 5kHz ……………………………………………………………………………………………………..