Graco 261830 Repair Manual page 10

Electric airless sprayer
Hide thumbs Also See for 261830:
Table of Contents

Advertisement

Problem
Low Output
10
What To Check
(If check is OK, go to next check)
1. Worn spray tip.
2. Verify pump does not continue to
stroke when gun trigger is
released.
3. Prime valve leaking.
4. Suction tube connections.
5. Electric supply with volt meter.
Meter must read 100-130 Vac.
Low voltages reduce sprayer per-
formance.
6. Extension cord size and length.
7. Leads from motor to circuit board
for damaged or loose wire con-
nectors. Inspect wiring insulation
and terminals for signs of over-
heating.
8. Worn motor brushes which must
be greater than 1/4 in. (6 mm).
9. Motor brushes binding in brush
holders.
10. Low stall pressure. Turn pressure
control knob fully clockwise.
11. Motor armature for shorts by
using an armature tester
(growler) or perform spin test,
page 15.
What To Do
(When check is not OK, refer to this column)
Relieve pressure, page 6. Replace tip. Refer
to gun instruction manual, 311979.
Service pump. See page 12, Displacement
Pump Replacement.
Relieve pressure, page 6. Then repair prime
valve. See page 23, Manifold Replacement.
Tighten any loose connections. Check o-ring
on suction tube.
Reset building circuit breaker; replace building
fuse. Repair electrical outlet or try another
outlet.
Replace with a correct, grounded extension
cord. See page 5, Grounding and Electric
Requirements.
Be sure male terminal pins are centered and
firmly connected to female terminals. Replace
any loose terminals or damaged wiring.
Securely reconnect terminals.
Replace brushes. See page 17. Motor Brush
Replacement.
Clean brush holders. Remove carbon dust by
using compressed air to blow out brush dust.
Replace pressure control assembly. See
page 21, Pressure Control Assembly
Replacement.
Replace motor. See page 26, Motor
Replacement.
Troubleshooting
311990F