Advanced Test; In Case Of Errors In The Communication - Shure LEGENDARY PERFORMANCE DDS 5900 Upgrade Manual

Hide thumbs Also See for LEGENDARY PERFORMANCE DDS 5900:
Table of Contents

Advertisement

DIS Digital Conference System

Advanced test

When clicking 'View/View Communication Window' a window showing all communication to the CU opens.
The following list summarises some useful
commands in case communication problems with
the cables occur:
Command
Description
avr
Automatic Version Request
dve
Display Version
erc
Errors on CU
List errors received. After the
list of error counts has been
printed. If the command name
is folowed by a '!' the counters
are reset.
erd
Error Received In Detail
Checking error received on the
CU
lic
License Info
reset
Reset
ru
Reset Unit - soft/hard
seatnames
List Seat Names
seats
List Seat definitions
sm0
Disable monitoring
sm1
Normal monitoring speed
ucc
Display Units With Chip card
uco
Display Units Connected
In case of errors in the
communication
If errors are present, fault-finding must be done.
The error can be one or more of the following:
1. Defective cable
2. One plug on the cable not inserted all the
way into the socket in the unit.
3. Contaminated plug/socket
4. Defective auto termination in the last unit
5. Defective CU
6. Defective Unit.
Try narrowing the list by systematic fault finding
Check the communication during the fault-
finding in the 'View Error status Window'
9
Upgrade Manual

Advertisement

Table of Contents
loading

Table of Contents