Check 'Dcs-Lan' Communication; Checking Using 'Error Status' Window - Shure LEGENDARY PERFORMANCE DDS 5900 Upgrade Manual

Hide thumbs Also See for LEGENDARY PERFORMANCE DDS 5900:
Table of Contents

Advertisement

DIS Digital Conference System

Check 'DCS-LAN' communication

Checking using 'Error Status' window

The error in the communication to the CU/CCU can be checked clicking 'View/View Error status Window':
Basically this window shall show no errors in the
system. However in large system, there might be
generated some error during start-up. You can
reset the error counter by clicking 'Reset error
counters in CU/CCU'. After resetting the
counters, no error must be present. If a counter
is counting up, it is a clear indication, that there
are communication errors.
IMPORTANT: DON'T DO ANY UPGRADE IF
THERE ARE ERRORS IN THE
COMMUNICATION.
If units are to be checked click the 'Switch to
Operation Mode' and then perform am AIB,
Automatic In-bus test.
The result must be 'OK' for all units.