Plasma panel replacement method
6.1.
Remove the rear cover
1. See Service Hint (Section 5)
6.2.
Remove the rear terminal
cover
1. Remove the screws (×5
2. Remove the rear terminal cover.
6.3.
Remove the P-Board
Caution:
To remove P.C.B. wait 1 minute after power was off for
discharge from electrolysis capacitors.
1. Unlock the cable clampers to free the cable.
2. Disconnect the connectors (P2, P5, P9, P11, P12 and P25).
3. Remove the screws (×9
6.4.
Remove the PA-Board
1. Unlock the cable clampers to free the cable.
2. Disconnect the connectors (PA3, PA4, and PA5).
3. Remove the screws (×3
, ×5
, ×2
, ×2
).
) and remove the P-Board.
) and remove the PA-Board.
6.5.
Remove the Tuner unit
1. Unlock the cable clampers to free the cable.
2. Disconnect the connectors (H3, H4, H12, DG1, and DG5).
3. Remove the screws (×4
10