20.0

Circuit Board Pin Assignments

1
JP20
1
JP19
3
5
7
9
1
JP9
3
5
7
9
11
13
Refer to pages 15-16 for additional jumper configuration details.
JP20-1
Not Used
JP19-1
On =°C
JP19-3
Not Used
JP19-5
Enables the logic for the Multi Color LED Light
JP19-7
Not used
JP19-9
Not Used
JP9-1
On
JP9-3
Not Used
JP9-5
Not used
On = 60A Logic
JP9-7
pages 15-16 for logic details)
JP9-9
On = 2 or 3 Pump Logic
JP9-11
On = 40A Logic (See pages 15-16 for logic details)
JP9-13
Not used
Page 68
1
JP20
850 LCD
REVX.XX
1
JP19
3
5
7
9
JP9
1
3
5
7
9
11
13
Off =°F
Off = 40/50A Logic (See Section 7.0
!
RISK OF SHOCK OR
ELECTROCUTION!
Turn power off
before servicing. This
task should only be
performed by a quali-
fied technician.
Off = 1 Pump Logic
DANGER