Freeze Down And Operation; Mix Inlet Regulator; Clean Control; Sanitizing Hopper - Stoelting Endura 111 Owner's Manual

Counter model gravity freezer soft serve
Table of Contents

Advertisement

In general, sanitizing may be conducted as follows:
A. Push the mix inlet regulator into hopper with air
inlet (long) tube toward the front of the freezer
(Fig.11).
Figure 11. Mix Inlet Regulator
B. Prepare 2 gallons (7.5 liters) of sanitizing solution
following manufacturer's instructions. Pour into hop-
per with mix inlet regulator in place.
C. Place the OFF-ON toggle switch in the ON position
while pressing the CLEAN switch. Check for leaks.
(Fig. 12.)
Figure 12. Clean Control
D. Clean sides of hopper, mix inlet regulator and under
side of hopper cover using a sanitized soft bristle brush
dipped in the sanitizing solution. (Fig. 13).
Figure 13. Sanitizing Hopper
E. After five minutes, place a bucket under the spigot and
open spigot to drain sanitizing solution. When solution
has drained, press the CLEAN snap switch to stop the
auger. Allow the freezer barrel to drain completely
(Fig. 14).
Figure 14. Draining Solution

3.4 FREEZE DOWN AND OPERATION

This section covers the recommended operating proce-
dures to be followed for the safe operation of the freezer.
A. Sanitize just prior to use.
B. Place the OFF-ON switch in the OFF position.
C. With spigot open, pour approximately 1 gallon (3.8
liters) of mix into the hopper. Allow the mix to flush out
about 8 ounces (0.23 liters) of sanitizing solution and
liquid mix. Close the spigot.
D. Fill hopper with approximately 3 gallons (11.4 liters) of
pre-chilled (40°F or 4°C) mix.
DO NOT OVERFILL THE HOPPER. MIX LEVEL
MUST NOT BE HIGHER THAN THE AIR INLET
TUBE ON THE MIX INLET REGULATOR.
E. The freezer barrel will automatically fill until it is about
1/2 full. If freezer barrel does not fill, check for obstruc-
tion in the mix inlet regulator. If freezer barrel fills over
1/2 full, indicated by low overrun, check for leaks at the
mix inlet regulator "O" Ring or check if the mix inlet
regulator was installed correctly or that the freezer is
level.
F. Place the OFF-ON switch in the ON position, then
press the PUSH TO FREEZE switch until the freezer
starts.
After the gearmotor starts, there is a 3 second de-
lay before the compessor starts.
9
CAUTION
NOTE