11. Adjustment of timing of take-up lever to needle
Checking
1. Bring needle bar to its lowest position.
2. Check to see if arm of take-up lever (A) is located at position (C) where one of 3
screws on take-up operating gear plate (B) is hidden by the arm,
A
Adjustment
1. Loosen two hex screws on main shaft gear (E) which is engaged with take-up
operating gear (D).
2. While inserting screw driver into accessible hex screw, turn main shaft gear (E) in
either way to get correct timing of take-up lever to needle.
3. Tighten 2 screws securely after adjustment.
B
C
E
D